Chapter 6
Certification
Oscillatory
HV Impulse
Dielectric Strength
Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60068-2-6
IEC 60068-2-27
44
Description
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Signal ports
DC Power ports
AC Power ports
Description
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Vibration
Shock
2.5 kV common and differential mode @ 1MHz
2.5 kV common and differential mode @ 1MHz
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (non-condensing),
55 °C (131 °F), 96 hours
2 g @ 10-150 Hz
30 g @ 11 ms
RUGGEDCOM RS416P
Installation Guide
Test Levels
± 4 kV
± 4 kV
± 4 kV
2.5 kV common mode @ 1MHz
5 kV (Failsafe Relay)
5 kV
5 kV
2 kVAC (Failsafe Relay)
1.5 kV
2 kV
Severity Levels
Class 2
Class 2
EMC and Environmental Type Tests