Communicator Formats - Paradox Esprit 748ES Programming Manual

Hide thumbs Also See for Esprit 748ES:
Table of Contents

Advertisement

Streamline
Data
section
[2
]
[2
]
___/___
ND
ND
[2
]
___/___
ND
09
___ ___
/
___/___
___/___
___/___
10
___ ___
/
___/___

COMMUNICATOR FORMATS

Key
[2
]
ND
=
slow (1400Hz, 1900Hz, 10bps)
ADEMCO
[1]
= (1400Hz, 1800Hz, 10bps)
[2]
=
SILENT KNIGHT
[3]
=
SESCOA
(2300Hz, 1800Hz, 20bps)
[4]
=
RADIONICS
(40bps with 1400Hz handshake)
[5]
=
RADIONICS
(40bps with 2300Hz handshake)
All addresses from
300
ID codes corresponding to the values programmed. Values to be programmed should be selected from this table.
CID
R
EPORTING CODE
100:
AUXILIARY ALARM
110:
FIRE ALARM
111:
FIRE SMOKE
112:
COMBUSTION
113
WATER FLOW
114:
HEAT
115:
PULLSTATION
116:
DUCT
117:
FLAME
118:
NEAR ALARM
120:
PANIC ALARM
121:
DURESS
122:
SILENT PANIC
123:
AUDIBLE PANIC
130:
BURGLARY
131:
PERIMETER BURG.
132:
INTERIOR BURG.
133:
24HR BURGLARY
136:
BURGLARY OUTDOOR
137:
BURGLARY TAMPER
138:
BURGLARY NEAR ALARM
140:
GENERAL ALARM
150:
24 HOUR AUX
151:
GAS DETECTED
152:
REFRIGERATION
153:
LOSS OF HEAT
154:
WATER LEAKAGE
155:
FOIL BREAK ALARM
156:
DAY TROUBLE ALARM
157:
LOW GAS LEVEL
158:
HIGH TEMPERATURE
159:
LOW TEMPERATURE
161:
LOSS AIR FLOW
For addresses
044
to
126
Description
Future use
1st digit: value must be entered i.e.
2nd digit: time correction (See table)
1st digit: telephone 1 format
2nd digit: telephone 2 format
1st digit: PGM 1 type
2nd digit: PGM 2 type
PGM 1
PGM 2
PGM mask 1
PGM mask 2
fast (1400Hz, 1900Hz, 20bps)
PROGRAMMABLE CONTACT ID EVENT CODES
to
527
(sections
11
to
67
) programmed with values other than
P
ROG. VALUE
[2
] / [1]
ND
[2
] / [2]
ND
[2
] / [3]
ND
[2
] / [4]
ND
[2
] / [5]
ND
[2
] / [6]
ND
[2
] / [7]
ND
[2
] / [8]
ND
[2
] / [9]
ND
[2
] / [10]
ND
[2
] / [11]
ND
[2
] / [12]
ND
[2
] / [
]
ND
BYP
[2
] / [
]
ND
MEM
[2
] / [
]
ND
TRBL
[1] / [2 ]
ND
[1] / [1]
[1] / [2]
[1] / [3]
[1] / [4]
[1] / [5]
[1] / [6]
[1] / [7]
[1] / [8]
[1] / [9]
[1] / [10]
[1] / [11]
[1] / [12]
[1] / [
]
BYP
[1] / [
]
MEM
[1] / [
]
TRBL
[2] / [2 ]
ND
[2] / [1]
, see pages 7 to 10.
Address
036
TIME CORRECTION:
037
(address
[2
]
ND
[2
[1]
038
[2]
[3]
039
[4]
[5]
[6]
[7]
040
041
042
043
[6]
=
RADIONICS
[7]
=
RADIONICS
[8]
=
ADEMCO
[9]
=
ADEMCO
[10]
=
ADEMCO
[
]
TRBL
=
DTMF
CID
R
EPORTING CODE
300:
SYSTEM TROUBLE
301:
AC LOSS
302
LOW SYSTEM BATTERY
305:
SYSTEM RESET
306:
PROGRAM CHANGED
309:
BATTERY TEST FAIL
320:
SOUNDER/RELAY TROUBLE
321:
BELL 1 TROUBLE
323:
ALARM RELAY TROUBLE
350:
COMMUNICATION TROUBLE
351:
TELCO 1 FAULT
354:
FAIL TO COMMUNICATE
370:
PROTECTION LOOP TROUBLE
371:
PROTECTION LOOP OPEN
372:
PROTECTION LOOP SHORT
373:
FIRE LOOP TROUBLE
382:
SENSOR TROUBLE
383:
SENSOR TAMPER
400:
OPEN/CLOSE
401:
OPEN/CLOSE BY USER #
402:
GROUP OPEN/CLOSE
403:
AUTOMATIC OPENING/CLOSING
404:
LATE TO OPEN/CLOSE
407:
REMOTE ARM DOWNLOAD
410:
REMOTE ACCESS
441:
OPEN/CLOSE - STAY MODE
570:
BYPASS
572:
24 HOUR ZONE BYPASS
573:
BURGLARY BYPASS #
574:
GROUP BYPASS
601:
MANUAL TEST
602:
PERIODIC TEST
625:
TIME/DATE RESET
- 3 -
037
second digit)
]
- No adjustment
[8]
- Minus
ND
- Plus
4 sec.
[9]
- Minus
- Plus
8 sec.
[10]
- Minus 12 sec.
- Plus 12 sec.
[11]
- Minus 16 sec.
- Plus 16 sec.
[12]
- Minus 20 sec.
- Plus 20 sec.
[
]
- Minus 24 sec.
BYP
- Plus 24 sec.
[
]
- Minus 28 sec.
MEM
- Plus 28 sec.
[
]
- Minus 32 sec.
TRBL
with PARITY (1400Hz, 40bps)
with PARITY (2300Hz, 40bps)
express
contact ID (programmable codes)
contact ID (all codes)
- no handshake (personal dialing)
[2
] [2
]
will report the contact
ND
ND
P
ROG. VALUE
[2] / [2]
[2] / [3]
[2] / [4]
[2] / [5]
[2] / [6]
[2] / [7]
[2] / [8]
[2] / [9]
[2] / [10]
[2] / [11]
[2] / [12]
[2] [
/
]
BYP
[2] [
]
/
MEM
[2] [
/
]
TRBL
[3] / [2
]
ND
[3] / [1]
[3] / [2]
[3] / [3]
[3] / [4]
[3] / [5]
[3] / [6]
[3] / [7]
[3] / [8]
[3] / [9]
[3] / [10]
[3] / [11]
[3] / [12]
[3] [
/
]
BYP
[3] [
/
]
MEM
[3] [
/
]
TRBL
[4] / [2
]
ND
[4] / [1]
[4] / [2]
PG748ES
4 sec.
8 sec.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents