Single Zone Connections - Paradox Esprit 748ES Programming Manual

Hide thumbs Also See for Esprit 748ES:
Table of Contents

Advertisement

The system hardware will recognize the following zone conditions:
Note: Keypad zones always use (1K
ZONE connection, without EOL resistor (N.C. contacts)
address 088, key [
] = "on"
MEM
key [10] = "off " (reset)
key [11] = "off " (reset)
N.C. contacts see Figure 1
ZONE connection, with EOL resistor (N.C. and N.O. contacts)
address 088, key [
] = "off" (reset)
MEM
key [10] = "off " (reset)
key [11] = "off " (reset)
N.C. and/or N.O. contacts, see Figure 2
ZONE connection, without EOL resistor, with tamper recognition (N.C. contacts)
address 088, key [
] = "on"
MEM
key [10] =
key [11] =
Tamper transmits separate code, see Figure 3
ZONE connection, with EOL resistor, with tamper recognition, and with wire fault
(short circuit) recognition (N.C. contacts)
address 088, key [
] = "off "
MEM
key [10] =
key [11] =
Tamper/wire fault transmits separate code, see Figure 4
) EOL resistor.
OHM

SINGLE ZONE CONNECTIONS

See "Tamper/wire Fault Definitions
"
and Options
See "Tamper/wire Fault Definitions
"
and Options
- 11 -
PG748ES

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents