Paradox Esprit 748ES Programming Manual page 12

Hide thumbs Also See for Esprit 748ES:
Table of Contents

Advertisement

ESPRIT 748ES WIRING DIAGRAM
Charging
and
battery test
LED
(every 60 seconds)
Battery charging current
Jumper off: 350mA
Jumper on: 700mA
**
BLACK
RED
+
**
To metallic enclosure
and grounding rod
UL: K12 Model T16 V75
ULC: Frost Model FTC 7516Q
Warning:
Improper connection may
result in damage to the system.
BELL OUTPUT 1A max.
UL/ULC: 650mA max.24 hr. stanby. Bell output
will shut down if current exceeds 3A.
*
Keypad software versions prior to 4.0 Keypad supervision must be OFF
Keypad software versions
FIRE RESET
To program PGM1 to conduct 4 second smoke detector reset when
[
]
and
[
]
are pressed simultaneously:
CLEAR
ENTER
039
[
]
Address
=
(first digit)
BYP
040
[5] [10]
Address
=
FIRE ALARM ZONE CONNECTIONS
* PGM maximum 50mA
+
Z3
*
PGM
AUX
Smoke
detector
Smoke
detector
Smoke detector
power supervision
relay, 12VDC
Smoke detector must be 4 wire latching -
UL Falcon model 5454, ULC BRK 2412.
Power supervision relay model MR3-UL.
780 Industrial Blvd., St-Eustache, Montreal, Quebec, Canada J7R 5V3 Fax: (450) 491-2313 http://www.paradox.ca
Caution: Disconnect battery before replacing fuse.
BATT
5 AMP
SERIAL
OUTPUT
+
AC
AC
PG1 PG2
AUX
COM
N.C.
N.0.
COM
BATT
AC
BELL
AUX
Z1
TRANSFO
16VAC 75VA
A.C.
POWER
AUX POWER 1.2A max.
UL/ULC 225mA max. for 24 hr. standby.
If you have additional wiring to connect to
BELL
auxiliary power, you can use the red (+) and
SIREN
black (-) keypad connectors. Aux. power will
shut down if current exceeds 3A.
UL /ULC: Wheelock 46T-12
}
}
4.0
onward
Keypad supervision must be ON
(See Address
042
[2
] [6]
Address
=
ND
056
[10] [10] [4]
Address
=
GROUND START CIRCUIT
COM
WHT
1K
W
EOL
Not permitted on UL listed systems
RESET
JUMPER
DIALER
xxx-xx
xxx
AUX
COM
COM
COM
COM
COM
Z2
Z3
COM
Z4
Z5
COM
Z6
AUX
COM
N.O. contacts
GREEN
1KW
EOL
RES
Smoke and heat detectors
Zone 3 = Fire zone if zone
*
definition is "24 hour".
Can be used as additional
aux. power terminals
For resistor values,
refer to 639
installation manuals.
090
, key
[11] [12]
)
Keyswitch can be used in
parallel with keypad (Not on
UL systems).
PGM
+AUX
BLK
RED
MR3-UL
YEL
RNG
BRN
GRY
GRN
RED
DIALER
RELAY
"TLM" LED
Short flash = OK
Long flash = Fault
OFF
Constant = On Line
AUX
COM
COM
COM
GRN YEL
KEYPAD
639
MAX 2 per system
Zone 13
Zone 14
NOTE: Keypad zones should
programmed as 24hr. zones.
KEYSWITCH CONNECTION
KEYSWITCH
PGM OUTPUT RELAY
WHT
BLK
MR3-UL
BRN
COM
Paradox Security Systems Graphic Dept
Warning:
Disconnect telephone
line before servicing.
= Disabled
*
Zone
13 or 14
N.O.
1K
W
EOL
N.C.
KEYPAD
616/636/646
MAX 5 per system
not
be
220W
KYPD GRN
KYPD BLK
PGM
+AUX
RED
YEL
N.C. N.O.
PRINTED IN CANADA - 09/01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents