Service and maintenance
8.2 Checking and changing lubricants
Procedure
1. Switch off the power supply to the drive unit.
2. Remove the geared motor and set it down as illustrated in the figure. The screw plug
must be on the top.
3. Remove the screw plug
4. Make a mark
5. Insert the dipstick
of the gearbox.
6. Pull the dipstick
7. Measure the distance "x" on the dipstick
8. Compare the value "x" with the value for distance "x".
9. Rectify the oil level if necessary and check it again.
10.Check the condition of the sealing ring on the screw plug
if necessary.
11.Seal the gearbox using the screw plug
12.Mount the geared motor.
You have now checked the oil level in the size 38 gearbox housing.
Figure 8-3
Table 8- 3
Gearbox type
E.38
Z.38
D.38
62
on a suitable dipstick
vertically into the opening until the mark
out vertically.
Dipstick
Mark
Distance "x"
Values for max. distance "x"
Distance "x"
[mm]
B5
B14
44
87
81
.
.
.
.
V1
V3
V18
V19
24
18
56
33
31
26
Operating Instructions, 02/2018, A5E38093846A/RS-AC
is level with the surface
and replace the sealing ring