2
SYSTEM CONFIGURATION
Shows the system configuration for the inter-module synchronization function.
2.1

Precautions for System Configuration

Lists precautions for configuring the inter-module synchronization function system.
Item
Modules targeted for inter-module synchronization function
For
Network compatible with inter-module synchronization
configuration
function
that uses the
Number of network modules that can be specified as
network
target module for inter-module synchronization function
module as the
(Per station include those on extension base unit.)
synchronization
Network transmission path format compatible with inter-
target module.
module synchronization function
Mounting position of local station module in
synchronization target network module
Types of stations supported with inter-module
synchronization function
Time required for inter-module synchronization function
to start (rising edge)
*1 This is not restricted by the module mounting position, maximum number of mountable modules, or the number of CPU modules when
using a multiple CPU system configuration. (Same as when not using the inter-module synchronization function.) ( MELSEC iQ-R
Module Configuration Manual)
*2 In the multiple CPU system, the inter-module synchronization function can be used only by the network module controlled by the CPU
No.1.
*3 If the local station is designated as the module targeted for the inter-module synchronization function, the master station on the same
base unit as the local station cannot be set as a module targeted for the inter-module synchronization function.
Master station
Local station
*4 A hub compatible with the inter-module synchronization function must be used. ( MELSEC iQ-R Ethernet/CC-Link IE User's Manual
(Startup))
*5 Shows the type of station that can be selected with the station type setting. ( MELSEC iQ-R CC-Link IE Field Network User's Manual
(Application))
*6 To use the module on the local station as the synchronization target module, Inter-module Synchronization Master Setting is required.
(Page 9 Inter-module synchronous master, Page 34 Inter-Module Synchronization Setting)
2 SYSTEM CONFIGURATION
8
2.1 Precautions for System Configuration
*1
*5
Master station
Local station
Description
This function can be used only with the MELSEC iQ-R Series modules.
(Page 10 Configuration Devices)
Only CC-Link IE Field Network
• Master station modules: 8 modules
• Local station modules: 1 module
*2*3
Only the following network topology can be used.
• Line topology
*4
• Star topology
• Line topology and star topology combination
The local station can be mounted only on the main base unit. (Local stations on
the extension base unit cannot be synchronized.)
Only master station and local station
Max. 20 seconds
*6