Use only a source of AC power that complies with local building and electrical
codes and has both overload and ground-fault (earth-fault) protection.
The 0.75 mm
6 A and can supply only one fixture with mains power. Do not connect any device
to the fixture's MAINS OUT socket when using this input cable.
Before you can connect other devices to the fixture's MAINS OUT socket, you
must use one of the 16 A rated power input cables available as optional
accessories from Martin to connect the fixture to power at the MAINS IN socket.
Use one of the 16 A rated power relay cables available as optional accessories
from Martin to relay power from the fixture's MAINS OUT socket to the MAINS IN
socket of the next fixture. If you link fixtures to power in a chain in this way, do not
exceed the following limits:
Connect a maximum of four (4) ELP PROFILE fixtures in total to power in a
chain at 100-120 V, or
Connect a maximum of nine (9) ELP PROFILE fixtures in total to power in a
chain at 200-240 V.
Before using the fixture, check that all power distribution equipment and cables are
in perfect condition, are rated for the current requirements of all connected devices,
and are of suitable type for the location (including water, pollution, temperature and
UV resistance).
The voltage and AC frequency of the power at the MAINS OUT socket are the
same as those applied at the MAINS IN socket.
Isolate the fixture from power immediately if any seal, cover, cable, or other
component is damaged, defective, deformed or showing signs of overheating. Do
not reapply power until repairs have been completed
Do not immerse the fixture in water or any other fluid. Do not install the fixture in a
location where flooding may occur.
Protection from burns and fire
Do not operate the fixture if the ambient temperature (Ta) exceeds 45° C (113° F).
The surface of the fixture can reach up to 55° C (131° F) if the fixture is operated at
the maximum permitted ambient temperature. Allow the fixture to cool for at least 5
minutes before handling.
Install the fixture on a non-combustible surface (brick, concrete, plaster etc.) only.
Do not aim the fixture towards combustible materials (fabric, wood, paper etc.) that
are within 50 cm (19 in.) of the fixture.
Keep the fixture well away from flammable materials (volatile liquids etc.).
Ensure that there is free and unobstructed airflow around the fixture.
Allow at least 0.2 m (8 in.) free space around the fixture.
Do not attempt to bypass thermostatic switches or fuses.
Do not modify the fixture in any way not described in this manual or install other
than genuine Martin® parts. Do not stick filters, masks or other materials onto any
lens or other optical component. Use only accessories approved by Martin® to
modify the light beam.
Protection from eye injury
Warning! Risk Group 3 (high risk) product according to EN 62471 and IEC/TR
62778.
Do not look directly into the product's light output.
6
2
/ 18 AWG mains power input cable supplied with the fixture is rated
Martin ELP CL Profile user guide