7

FAULT-TRACING

Try these recommended checks and inspections before sending for an authorised
service technician.
Type of fault
No arc.
The welding current is
interrupted during welding.
The thermal cut-out trips
frequently.
Poor welding performance.
8

ORDERING SPARE PARTS

Repair and electrical work should be performed by an authorised ESAB service
technician. Use only ESAB original spare and wear parts.
Tig 2200i AC/DC is designed and tested in accordance with the international and Euro­
pean standards IEC/EN 60974-1, 60974-3 and IEC/EN 60974-10 . It is the obligation of
the service unit which has carried out the service or repair work to make sure that the
product still conforms to the said standard.
Spare parts may be ordered through your nearest ESAB dealer, see the last page of
this publication.
9

DISMANTLING AND SCRAPPING

Welding equipment primarily consists of steel, plastic and non-ferrous metals, and must
be handled according to local environmental regulations.
Coolant must also be handled according to local environmental regulations.
Dispose of electronic equipment at the recycling facility!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic
Equipment and its implementation in accordance with national law, electrical and/or
electronic equipment that has reached the end of its life must be disposed of at a
recycling facility.
As the person responsible for the equipment, it is your responsibility to obtain
information on approved collection stations.
For further information contact the nearest ESAB dealer.
bt33d1ea
Corrective action
S
Check that the mains power supply switch is turned on.
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that the correct current value is set.
S
Check the mains power supply.
S
Check to see whether the thermal cut-outs have tripped.
S
Check the mains power supply fuses.
S
Make sure that you are not exceeding the rated data for the
welding power source (i.e. that the unit is not being
overloaded).
S
Check that the welding current supply and return cables are
correctly connected.
S
Check that the correct current value is set.
S
Check that the correct electrodes are being used.
S
Check the gas flow.