YASKAWA J1000 Technical Manual page 21

Rs-485; memobus/modbus interface; ac drive-j1000 option
Hide thumbs Also See for J1000:
Table of Contents

Advertisement

No.
Communication
H5-02
Speed Selection
Communication
H5-03
Parity Selection
Stopping
Method After
H5-04
Communication
Error
YASKAWA ELECTRIC TOBPC73060033A RS-485 Interface Technical Manual
6 Related Drive Parameters
Name
Description
Selects the baud rate for
MEMOBUS/Modbus
terminals R+, R-, S+ and S-.
Cycle power for the setting
to take effect.
0: 1200 bps
1: 2400 bps
2: 4800 bps
3: 9600 bps
4: 19200 bps
5: 38400 bps
Selects the communication
parity for MEMOBUS/
Modbus terminals R+, R-,
S+ and S-. Cycle power for
the setting to take effect.
0: No parity
1: Even parity
2: Odd parity
Selects the stopping method
when a communication
time-out fault (CE) is
detected.
0: Ramp to stop
1: Coast to stop
2: Fast-stop
3: Alarm only
Default
3
0
3
21