Appliance Break-In - Quadra-Fire EXCURSION-I Owner's Manual

Hide thumbs Also See for EXCURSION-I:
Table of Contents

Advertisement

G. Appliance Break-In
Initial Break-in Procedure
• The fireplace should be run three to four hours continuously
on high flame and high fan speed.
This cures the materials used to manufacture the fireplace.
NOTICE! This product comes equipped with a fan that
provides remote control of heat output. See Section H.
Set the fan speed to high on the RC400 remote control
during the first three to four hours of break-in operation.
This break-in will ensure optimum speed control of the fan
during subsequent use.
• Turn the fireplace off and allow it to completely cool.
• Remove decorative front and fixed glass assembly. See
Section 4.B.
• Clean fixed glass assembly. See Section 4.B.
• Verify Glass Seal Plate is properly installed. See Figure
3.6.
WARNING! Glass seal plate must be properly installed.
Risk of elevated component temps and carbon monoxide
exposure.
• Replace the fixed glass assembly and run continuously
on high an additional 12 hours.
Note: Some IPI systems have a safety feature that
automatically shuts down the fireplace after 9 hours of
continuous operation without receiving a command from the
remote control. If this occurs, restart the appliance.
• Verify collar slide plate screw is attached see Figure 3.5.
NOTICE! Open windows for air circulation during fire-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
Quadra-Fire • EXCURSION-I, EXCURSION-II, EXCURSION-III Owner's Manual • 2538-981 Rev. B • 2/19
12
GLASS SEAL PLATE
GLASS SEAL
PLATE INSTALLED
Figure 3.6 Glass Seal Plate

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EXCURSION-I and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Excursion-iiiExcursion-ii

Table of Contents