F. Appliance Break-In
Initial Break-in Procedure
When you light your appliance, you may notice that it
produces heat which does have an associated odor or
smell. If you feel this odor is excessive it may require the
initial three to four hour continuous burn on high followed by
a second burn up to 12 hours to fully drive off any odor from
paint and lubricants used in the manufacturing process.
Condensation on the glass is normal.
NOTE: The appliance should be run three to four hours
on the initial start-up. Turn it off and let it cool completely.
Remove and clean the glass. Replace the glass and run the
appliance for an additional 12 hours. This will help to cure
the products used in the paint and logs.
During this break-in period it is recommended that some
windows in the house be opened for air circulation. This will
help avoid setting off smoke detectors, and help eliminate
any odors associated with the appliance's initial burning.
!
Fire Risk.
High Temperatures.
Keep combustible household items away from
appliance.
Do NOT obstruct combustion and ventilation air.
• Do NOT place combustible items on top of or in front
of appliance.
• Keep furniture, draperies away from appliance.
!
• Prevent accidental appliance operation when not attended.
• Unplug or remove batteries from remote control if absent or
if appliance will not be used for an extended period of time.
• Property damage possible from elevated temperatures.
!
Smoke and odors released during initial operation.
Open windows for air circulation.
Leave room during initial operation.
Smoke may set off smoke detectors.
Smoke and odors may be irritating to sensitive individuals.
10
WARNING
CAUTION
CAUTION
Quadra-Fire • Hudson Bay • 3-90-7003998_R25 • 07/17
!
Fire Hazard.
Keep combustible materials, gasoline and other
flammable vapors and liquids clear of appliance.
Do NOT store flammable materials in the appliance's
vicinity.
• Do NOT use gasoline, lantern fuel, kerosene, charcoal
lighter fluid or similar liquids in this appliance.
• Combustible materials may ignite.
G. Heat Management
Heat Output
This model has a variable burn rate which is controlled by
the HI/LO switch on the control module. Therefore the flame
height is adjustable. It is located in the control cavity of the
appliance.
If a remote control is installed, the flame height may also be
controlled by the remote, if flame height is a function of that
particular model of remote control.
The fan speed is controlled by adjusting the speed control
knob. Turn the knob clockwise to increase the fan speed
and counterclockwise to decrease the fan speed.