Preparing The System For Operation - IBM 9040-MR9 Manual

Power systems. vital product data card
Hide thumbs Also See for 9040-MR9:
Table of Contents

Advertisement

Figure 7. Replacing the VPD card
Preparing the system for operation after removing and replacing the VPD card from the
9040-MR9
Follow these steps to prepare the system for operation after removing and replacing the vital product data
card.
Procedure
1. Ensure that you have the electrostatic discharge (ESD) wrist strap on and that the ESD clip is plugged
into a ground jack or connected to an unpainted metal surface. If not, do so now.
2. Replace the service access cover.
a) Lower the cover (A) onto the system unit. Ensure that the cover alignment pins (C) on each side of
the cover fit into the matching slots in the chassis.
b) Slide the cover (A) onto the system unit. Ensure that the tabs (D) tuck under the mesh along the
front opening of the chassis.
c) Close the release latches (B) by pushing it in the direction that is shown in the following figure.
10 Power Systems: Vital product data card for the 9040-MR9

Hide quick links:

Advertisement

Table of Contents