Service And Maintenance Intervals; 10 Hours Service - In-Line Filter; Hours Service - Nozzle Filters (Optional Equipment); 10 Hours Service - Spraying Circuit - Hardi EAGLE SPB BOOM Operator's Manual

Hide thumbs Also See for EAGLE SPB BOOM:
Table of Contents

Advertisement

Service and Maintenance intervals

10 hours service - In-Line filter

If the boom is equipped with In-Line Filters, unscrew the filter bowl to
inspect and clean the filter. When reassembling, the O-ring should be
greased.
Alternative filter meshes are available. See section on Technical
specifications - Filters and nozzles.
±
WARNING! Be careful not to splash out liquid when unscrewing
the filter bowl.
±
WARNING! Always wear protective clothing and gloves before
opening the filter!

10 hours service - Nozzle filters (optional equipment)

Check and clean.

10 hours service - Spraying circuit

Fill with clean water, operate all functions and check for leaks using higher spray pressure than normal. Check nozzle spray
patterns visually using clean water.

250 hours service - Readjustment of the boom

See section "Occasional maintenance".

250 hours service - Hydraulic circuit

Check the hydraulic circuit for leaks and repair if any.
±
WARNING! Hoses for boom lifting device must be changed after every 5 years of use.

250 hours service - Hoses and tubes

Check all hoses and tubes for possible damages and proper attachment. Replace damaged hoses or tubes.