Service and Maintenance intervals
10 hours service - In-Line filter
If the boom is equipped with In-Line Filters, unscrew the filter bowl to
inspect and clean the filter. When reassembling, the O-ring should be
greased.
Alternative filter meshes are available. See section on Technical
specifications - Filters and nozzles.
±
WARNING! Be careful not to splash out liquid when unscrewing
the filter bowl.
±
WARNING! Always wear protective clothing and gloves before
opening the filter!
10 hours service - Nozzle filters (optional equipment)
Check and clean.
10 hours service - Spraying circuit
Fill with clean water, operate all functions and check for leaks using higher spray pressure than normal. Check nozzle spray
patterns visually using clean water.
250 hours service - Readjustment of the boom
See section "Occasional maintenance".
250 hours service - Hydraulic circuit
Check the hydraulic circuit for leaks and repair if any.
±
WARNING! Hoses for boom lifting device must be changed after every 5 years of use.
250 hours service - Hoses and tubes
Check all hoses and tubes for possible damages and proper attachment. Replace damaged hoses or tubes.
6 - Maintenance
6.3