19. MSI

MSI On/Off
On
MSI Check Character
Different types of check characters are used with MSI bar codes. You can program the
scanner to read MSI bar codes with Type 10 check characters. Default = Validate Type
10, but Don't Transmit.
When Check Character is set to Validate Type 10/11 and Transmit, the scanner will
only read MSI bar codes printed with the specified type check character(s), and will
transmit the character(s) at the end of the scanned data.
When Check Character is set to Validate Type 10/11, but Don't Transmit, the unit will
only read MSI bar codes printed with the specified type check character(s), but will not
transmit the check character(s) with the scanned data.
* Validate Type 10, but Don't Transmit
Validate 2 Type 10 Characters, but Don't Transmit
50
GEOS SD 580 2D
Default MSI setting
Validate Type 10 and Transmit
Validate 2 Type 10 Characters and Transmit
*Off