INSTALLATION

Installation
Taps/valves
Use appropriate pressure taps. Open taps are not permitted.
Thermostatic pressure valves must be suitable for hydraulically
controlled instantaneous water heaters.
Note
Never use the shut-off valve in the cold water inlet to
reduce the flow rate. It is intended for shutting off the
appliance.
Permissible water pipe materials
- Cold water inlet pipe:
Galvanised steel pipe, stainless steel pipe, copper pipe or
plastic pipe
Material losses
!
If you use plastic pipework in the cold water inlet line,
you must observe the following condition:
f Install a metal pipe approx. 1 m in length at the ap-
f
pliance cold water connection. Then you can install
the plastic pipework.
- DHW outlet pipe:
Stainless steel pipe or copper pipe
Material losses
!
The instantaneous water heater is unsuitable for installa-
tion with plastic pipework in the DHW outlet line.
Flexible water connection lines
f Secure the back panel with an additional screw at the
f
bottom.
Undersink installation
1 Cold water Inlet
2 DHW outlet
www.stiebel-eltron.com
Oversink installation
1 Cold water Inlet
2 DHW outlet
10. Installation

10.1 Standard installation

- Electrical connection from below on unfinished walls
- Water connection on unfinished walls
For further installation options, see chapter "Installation / Instal-
lation / Installation alternatives":
- Power cable for finished walls
- Connecting a load shedding relay
- Water installation on finished walls
Opening the appliance
f Turn the cap anticlockwise. Remove by pulling it forward.
f
f Undo the screw.
f
1
f Pivot open the appliance cover.
f
2
Preparing the power cable
2
compact contr ol
compact contr
160
≥ 30
1
DHF-C |
23