Aw2 Wiring Example - HID ACW2-XN Installation Manual

Web-based access control solution
Hide thumbs Also See for ACW2-XN:
Table of Contents

Advertisement

Web-Based Access Control Solution
ACW2-XN

AW2 Wiring Example

Terminal blocks unplug, giving easy
access to the terminal screw heads
12V DC
PSU
Maglock – Door #1
REX – Door #1
DPS – Door #1
Wiegand Reader #1
Colour
Red
Black
Green
White
Brown
Orange
Yellow
Blue
Grey
*DPS: Some electric strike locks include Door Position Sense terminals. When they don't, additional
sensors should be fitted if door position sensing is required.
Some strike locks and maglocks have built-in arc suppression. Consult the installation information for the
locks you are using. It is recommended that the MOVs (supplied with the Wiegand Module) are
connected across any inductive loads. NB: The supplied MOVs are only suitable for 12V applications.
CAUTION:
Inadequate spark suppression can result in early failure of relay contacts – and will void the
warranty on the affected AW2 module.
Page 10 of 26
0V
+12V
NC
COM
Function
12V
0V
D0
D1
RED
GREEN
Buzzer
Hold
Shield
Installation Guide
Strike Lock – Door #2
COM
*DPS
NO
REX – Door #2
Wiegand Reader #2
Function
Shield
Hold
Buzzer
GREEN
RED
D1
D0
0V
12V
© 2018 HID Global Corporation All rights reserved.
Colour
Grey
Blue
Yellow
Orange
Brown
White
Green
Black
Red