HID EDGE EVO EH400-K Installation Manual

HID EDGE EVO EH400-K Installation Manual

Standard networked controller

Advertisement

I N STAL L ATI ON G UI DE
EDGE EVO®
Standard Networked Controller
EH400-K/ESH400-K
EDGE EVO is the next evolution in access control hardware solutions. A true IP solution that meets the demands of
open architecture, IP-centric environments, EDGE EVO provides fully distributed intelligence and decision making right
to the door, leveraging the IT infrastructure to the maximum extent possible. Leveraging Power-over-Ethernet (PoE),
EDGE EVO reduces door installation costs by not requiring a separate local power supply under many circumstances.
The Standard Networked Controller is a fully integrated single-door controller offering discrete I/O and Wiegand/
Clock-and-Data interfaces to readers. Additionally, connect native Hi-O™ devices (readers, locks, pushbuttons) and
EDGE EVO Hi-O Modules to the Hi-O bus, providing secure communication around the door. Hi-O involves devices with
built-in intelligence and a CANbus that links all the devices together. Password protect or encrypt Hi-O CANbus data
traffic. Each Hi-O device (such as the push plate, electric strike, card reader and door operator) is connected to the
CANbus by a single, four-wire cable. Two wires supply power and the other two are used for data communication.

Specifications

CONDITIONS
DC Input (NSC)
DC Input (MAX)
Supervised inputs
(AC, Batt, REX, Door Mon) (MAX)
Data 1/CLK , Data 0 / Data (MAX)
GRN LED, RED LED, Beep, Hold (MAX)
External Tamper (MAX)
AUX 12/24 VDC Input
CAN DC
PWR Output
(MAX)
PoE Input
AUX 12 VDC
Reader DC
PWR Output
AUX 24 VDC
(MAX)
PoE Input
AUX 12 VDC
Input
AUX 24 VDC
Strike***/
Input
AUX Relays
NC or NO
DC Output
(MAX)
PoE Input
AUX/PoE
Input
Legend
AUX = Auxillary input or output
CAN = CANbus
NSC = Normal Standby Condition
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
© 2014 - 2017 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID Brick logo, the Chain Design, iCLASS, EDGE EVO, and Hi-O are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other countries and may not be used without permission. All other trademarks, service marks, and product
or service names are trademarks or registered trademarks of their respective owners.
VOLTAGE DC
+12 VDC
+24 VDC
PoE (+48 VDC NOM) 0.085 Amp   4.08 W
+12 VDC
+24 VDC
PoE (+48 VDC NOM)
0-+5VDC Reference
+5VDC (NOM)
+10.8 to +24 VDC
+ 24 VDC (NOM)
+9.8 to +12.25 VDC
+10 to +12 VDC
Unregulated
(Wet) Jumpers
+23 to +24 VDC
Regulated (Wet)
Jumpers - 12 VDC +10 to +12 VDC
Unregulated
+16.5 to +24 VDC
(Wet) Jumpers
Regulated (Wet)
+10 to +12 VDC
Jumpers - 12 VDC
Jumpers Set to
+12 to +24 VDC
Dry
External
PoE = Power over Ethernet
NC = Normally Closed
NO = Normally Open
An ASSA ABLOY Group brand
OPERATING
CURRENT
POWER
TEMPERATURE
0.18 Amp 
 2.16 W
0.14 Amp
  3.36 W
  1 8.00 W
  1 .50 Amp
36.00 W
0.30 Amp
14.40 W
0.005 Amp
  0.025  W
(sink)
N/A
N/ A
0.005 Amp
 0.025  W
(sink)
0.02 Amp
0. 1 00 W
  1 .2 Amp*
28.80 W
0.4 Amp*
 9.60 W
32° - 122°F
(0° - 50° C)
0.32 Amp*
3.92 W
0.60 Amp*
7.35 W
0.58 Amp*
7.11 W
8.40 W
0.70 Amp*
16.80 W
8.40 W
0.36 Amp* 8.64 W
0.58 Amp* 6.96 W
2 .00 Amp ** 48.00 W
* Combined output ratings not to exceed V*I = W:
• 1.2 Amp (+ 24 VDC Aux Input, 28.8 W)
• 1.2 Amp (+ 12 VDC Aux Input, 12.96 W)
**  Each relay
***  S hared between each relay
82000-921, Rev. D.3
REGULATORY
CABLE LENGTH
REF NUMBER
Hi-O CANbus
Total Length:
100 ft (30 m)
22 AWG
0.65 mm
0.33 mm
2
Maximum between drops:
30 ft (10 m)
KE400CX
22 AWG
0.65 mm
0.33 mm
2
RJ-45
328 ft (100 m)
Category 5 K
Regulatory Reference
Number Deciphering
X
= K for Black
1
G for Gray
X
= N for non-Solo
2
S for Solo
X
N
1
2

Advertisement

Table of Contents
loading

Summary of Contents for HID EDGE EVO EH400-K

  • Page 1 © 2014 - 2017 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID Brick logo, the Chain Design, iCLASS, EDGE EVO, and Hi-O are trademarks or registered trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other countries and may not be used without permission. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
  • Page 2 EDGE EVO I N STALLATI ON GUI DE 82000-921, Rev. D.3 Installation Power Analysis Before starting installation, determine which components will be used in the system and analyze the power requirements to avoid over-loading the EDGE EVO Hi-O Networked Controller & Reader (EH400-K).
  • Page 3 EDGE EVO I N STALLATI ON GUI DE 82000-921, Rev. D.3 Step    3 Analyze Power Requirements A - Door Peripheral Operational Currents For the door peripherals identified in Step    1 Identify System Components, consult the vendor data sheets to determine the operational current draw. Typical operational current draw is provided below.
  • Page 4 EDGE EVO I N STALLATI ON GUI DE 82000-921, Rev. D.3 Step    4 Select Power Scheme Select the appropriate power scheme to meet overall current draw. Using the analysis from the previous sections equates to the following two power scheme options. Power Scheme 1 Standard Networked Controller power is derived from PoE.
  • Page 5 EDGE EVO I N STALLATI ON GUI DE 82000-921, Rev. D.3 Mounting Junction box not included. ATTENTION Observe precautions for handling Wiring ELECTROSTATIC SENSITIVE DEVICES Restore Network Defaults Jumper Hi-O Group Select Jumper GRP SEL Short = Group 1, Open = Group 2 Outside Door Inside Door CAN_L...
  • Page 6 Discovery GUI (for DHCP Networks) With a DHCP network, use the HID Discovery GUI on the PC to locate and connect the Controller. Note: The Controller must be connected to the network before power is applied for DHCP to function.
  • Page 7 EDGE EVO I N STALLATI ON GUI DE 82000-921, Rev. D.3 Configure The web browser will prompt for login information. Note: To correct errors in the controller Network Configuration or if the admin password is not available, see Appendix B: Troubleshooting. Login admin Password...
  • Page 8 EDGE EVO I N STALLATI ON GUI DE 82000-921, Rev. D.3 Appendix A Hi-O Interface Modules Hi-O interface modules are used to interface the EDGE EVO Networked Controller. Hi-O interface modules connect the native Hi-O bus with additional components around and behind doors and other access points.
  • Page 9 EDGE EVO I N STALLATI ON GUI DE 82000-921, Rev. D.3 Appendix B Troubleshooting See Section 3: Wiring to clarify the procedures in this appendix. Network Defaults Jumper Procedures Use the applicable Network Defaults Jumper procedure to correct potential errors in an EDGE EVO and EDGE EVO Solo controller Network Configuration or if the admin password is not available.
  • Page 10 8. Remove the jumper to complete the process. 9. The beeps will cease. The admin password is now reset to the value provided by HID Global Technical Support. The unit will beep quickly 10 times and then automatically reboot.
  • Page 11 • Left side PCB (door interface board): attach a jumper wire from P3 pin 1 to P3 pin 2. CAUTION: The EH400-K ships from HID Global with these jumpers pre-installed on the connectors. Removing these jumpers causes false tampers to trigger.
  • Page 12 All splices and connections shall be mechanically secure and bonded electrically. EDGE EVO was evaluated for use with all Listed HID Global Wiegand models: iCLASS, Indala Prox, HID Prox, bioCLASS, SmartID, SmartTRANS, and Mag Stripe series (with and without keypad), up to 128-bit formats. EDGE EVO was evaluated for use with all HID Global Hi-O iCLASS readers.

This manual is also suitable for:

Edge evo esh400-k

Table of Contents