Installation Instructions; Safety Warnings - STEINEL IS 2160 ECO Information Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 8

Installation instructions

Dear Customer,
been manufactured,
tested and packed with
Congratulations on pur-
the greatest care.
chasing this STEINEL Inf-
Please familiarise yourself
rared Sensor and thank
with these instructions
you for the confidence
before attempting to in-
you have shown in us.
stall the sensor since
You have chosen a high-
prolonged reliable and
quality product that has
Principle
The integrated pyroelec-
With a detection angle of
tric infrared detector
160° and a max. reach of
senses the invisible heat
12 m the sensor watches
radiated from moving
over an area of approx.
objects (people, animals,
165 m
2
etc.). The heat detected is
to cover a smaller area,
electronically converted
reach may be reduced
into a signal that switches
by tilting the sensor unit.
on loads (e.g. a light) con-
Using the swivel mount
nected to it. Heat is not
supplied, the sensor
detected through obsta-
unit can also be turned
cles, such as walls or
horizontally, making it
panes of glass. Heat ra-
possible to target the
diation of this type will,
detection zone exactly
therefore, not trigger the
as you choose. The
detection angle can also
sensor.

Safety warnings

Installation of the
Disconnect the power
sensor involves work
before attempting any
on the mains power
work on the motion
supply. This work must
detector.
therefore be carried
The electrical connec-
out professionally in
tion lead must be dead
accordance with the
during installation.
applicable wiring regu-
Therefore, switch off
lations and electrical
the power first and
operating conditions.
use a voltage tester to
(
check that the power
D
- ÖVE-EN 1,
supply is disconnected.
A
- SEV 1000).
12
trouble-free operation will
only be ensured if it is
installed properly.
We hope your new Infra-
red Sensor will give you
lasting satisfaction.
(s. fig. page 2)
be adjusted to suit individual
requirements by fitting
shrouds.
. If you only wish
Important: the safest mo-
tion detection is obtained
when the device is moun-
ted and aligned laterally to
the walking direction and
no obstacles (such as
trees and walls, for ex-
ample) obstruct the view.
Please note that the
sensor must be pro-
tected by a 10 A circuit
breaker. The mains
supply lead must be
no greater than 10 mm
in diam-eter.
- VDE 0100,
Installation
The site of installation
Note: For surface-mount-
should be at least 50 cm
ed wiring, it is recommen-
from a light because heat
ded to install the swivel
radiated from it may trig-
mount  (see below).
ger the sensor uninten-
Alternatively, the unit may
tionally. To obtain the spe-
be pierced at the thinner
cified reach of 12 m, the
section to pass the cable
through. 5. Screw mount-
sensor should be installed
at a height of approx. 2 m.
ing plate  to wall.
Please ob-serve the safe-
ty warnings on page 12.
6a) Connecting the
mains lead
Installation procedure:
The mains lead consists of
1. Undo screws on hous-
a 2-3 phase cable
ing  2. Do not detach
L
= phase conductor
wir-ing from terminal
N
= neutral conductor
block, but gently pull
PE = protective-earth
entire terminal assembly,
conductor
including sensor unit 
(cylindrical section), to
If you are in any doubt,
remove it.
you must identify the
3. Hold mounting plate 
cables using a voltage te-
against wall/ceiling, mark
ster; then disconnect the
drill holes, paying atten-
power supply again.
tion to wiring runs con-
The phase (L) and neutral
cealed in wall/ceiling. Drill
conductor (N) are connec-
holes, insert wall plugs
ted according to terminal
(6 mm). 4. Break open
assignment. The protecti-
pre-punched cable entry
ve-earth conduct-or is
holes as appropriate for
connected to the earth
concealed  or surface-
terminal
mounted  installation,
A mains switch for 'ON'
insert grommets, pierce
and 'OFF' switching can
and pass cable through.
of course be installed in
the mains lead.
Installation with swivel mount
The swivel mount  allows
provided with sensor unit.
2. Hold swivel mount 
you to turn the motion
against wall and mark drill
detector horizontally. This
holes, drill the holes, insert
provides additional adju-
wall plugs, pass cable
stment for the detection
zone.
through. Connect as de-
1. Press cupped pieces
scribed in „Installation".
3. Pass screws through
 out of swivel mount 
(s. fig. page 3)
6b) Connecting the load
supply lead
The load supply lead (e.g.
light) is also a 2 to 3-core
cable which is connected
to terminals N and L'. The
live conductor must be
connected to the terminal
marked L'.
Connect the neutral con-
ductor to the terminal
marked N together with
the neutral conductor of
the mains power supply
lead. The protective-earth
conductor is connected to
the earth terminal
7. Once wiring is complet-
ed, insert terminal block
together with sensor unit
 into mounting plate ,
fit housing cover  and
secure in place with faste-
ning screws.
.
cupped pieces  and
secure swivel mount  in
such a way that the screw
head is positioned on the
smooth side and the
domed side rests against
the mounting plate  (see
diagram).
.
13