2 For the User

Maintenance
Safety valve (not supplied)
The safety valve must be inspected regularly, about 4
times a year, to prevent blockages. To inspect the valve,
open the safety valve manually and check that water
flows through the overflow pipe. If this does not happen,
the safety valve is defective and must be replaced.
The safety valve sometimes releases a little water after
hot water has been used. This discharge is caused by the
expansion of cold water entering the water heater, res-
ulting in a pressure increase, whereby the safety valve
opens.
Emptying
1. Shut off the incoming cold water.
2. Open the drain connection, or the drain valve if fitted.
During draining, air must be let into the water heater by
loosening a hot water connector (XL4) or opening a hot
water tap.
To ensure that the water heater drains completely, a
hose, or a pipe, with an outlet below the lowest level of
the water heater must be attached to the drain connec-
tion or drain valve. When installed in a location that is
exposed to the risk of frost, the water heater must be
emptied whenever it is not in operation. Freezing will
result in the water heater bursting.
Service
For service, contact the installer. Serial number (PF3) (14
digits) and installation date should always be stated.
Only replacement parts supplied by NIBE may be used.