Set Time Of Day - Hellenbrand H-125 Series Owner's Manual

Water conditioning system
Hide thumbs Also See for H-125 Series:
Table of Contents

Advertisement

SET
TIME HOUR
6:35
PM
SET
TIME MINUTES
6:35
PM
SET
RETURN TO ROTATING DISPLAY
WATER HARDNESS
20
SET
DAYS BETWEEN REGEN
14
SET
REGEN TIME HOUR
2:00
AM
SET
REGEN TIME MINUTES
2:00
AM
SET
RETURN TO ROTATING DISPLAY
8

SET TIME OF DAY

=  Up Arrow
STEP 1
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using  or  buttons. AM/PM
toggles after 12. Press NEXT to go to step 3.
STEP 2
Step 3 - Current Time (minutes): Set the minutes of day using  or  buttons. Press
NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss - Lithium battery on circuit board provides up to 2 years of time clock backup
during power outages. If the power is out when battery is depleted, only time of day needs
to be reset, all other values are stored in non-volatile memory. When time of day is flashing,
replace lithium coin type 2032 battery.
STEP 3
Battery back-up feature will be activated after 24 hours of power.
Do not forget to reset for daylight savings time.
Figure 9
Step 1 - Press NEXT and  simultaneously for 3 seconds.
STEP 1
Step 2 - Hardness: Set the amount of total compensated hardness in grains (hard-
ness as calcium carbonate) per gallon using  or  buttons. The factory setting is
20 with value ranges from 1 to 150 in 1 grain increments. Note: The grains per gallon
should be increased if soluble iron needs to be reduced.
for each ppm of iron present. If this display shows nA -, then system is set-up in "filter"
STEP 2
mode or "AUTO" is not selected in softener system setup. (See page 33). Press
GR
NEXT to go to Step 3. Press REGEN to exit Installer Displays/Settings.
Step 3 - Day Override: This sets the number of days between regenerations. If value
set to "oFF" regeneration initiation is based solely on gallons used. If value is set as
a number (allowable range from 1 to 28) a regeneration initiation will be called for on
that day even if sufficient number of gallons were not used to call for a regeneration.
STEP 3
Set Day Override using  or  buttons: Factory setting is 14 days.
• number of days between regeneration (1 to 28); or
• "oFF"
See pages 9-13, for more detail on softener setup. Press NEXT to go to step 4. Press
REGEN to return to previous step.
Step 4 - Regeneration Time (hour): Set the hour of day for regeneration using  or
STEP 4
 buttons. AM/PM toggles after 12. The factory setting time is 2:00 a.m. This display
will show "REGEN" "IMMEDIATE ON ZERO GAL" if "Immediate" is selected on Step
12 of softener set-up. See page 33. Press NEXT to go to step 5. Press REGEN to
return to previous step.
Note: When installing this unit as part of a multi unit parallel system the regen time of
day must be adjusted to prevent multiple units from regenerating at the same time.
STEP 5
Step 5 - Regeneration Time (minutes): Set the minutes of day for regeneration using
 or  buttons. This display will not be shown if system is set for immediate regen-
eration. Press NEXT to exit Installer Displays/Settings. Press REGEN to return to
previous step.
Figure 10a
=  Down Arrow
INSTALLER DISPLAYS/SETTINGS
=  Up Arrow
=  Down Arrow