Honeywell THX9321 Prestige 2.0 Product Data page 49

Hide thumbs Also See for THX9321 Prestige 2.0:
Table of Contents

Advertisement

ISU
Installer Setup
Number
Name
5040
Which Sensors will
be used for
TEMPERATURE
Control? (Multiple
Sensors are
Averaged)
5050
What Terminals are
Wired to the
Outdoor
Temperature
Sensor?
5070
What Terminals are
Wired to the Return
Air Temperature
Sensor?
5080
Return Air
Temperature
Sensor Type
5090
What Terminals are
Wired to the
Discharge Air
Temperature
Sensor?
5100
Discharge Air
Temperature
Sensor Type
5110
A-Coil Low
Temperature Cutoff
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Thermostat (Internal)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
Sensor Name (Remote)
(Up to 6 Remote Sensors)
None
S1
S2
S3
S4
None
S1
S2
S3
S4
10K
20K
None
S1
S2
S3
S4
10K
20K
Off
35° F to 65° F (in 5° F increments)
®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
Residential,
Commercial
Default
or Both
Sensors are
Both
Averaged
(Internal and
Remote)
None
Both
None
Both
10K
Both
None
Both
10K
Both
Off
Both
49
Requires
EIM
Notes
No
Select the sensors to be used for
temperature control. If you select more
than one, the thermostat will average the
temperature readings from each sensor.
See "Remote Indoor Sensors" beginning
on page 130.
Yes
Wired Sensors requires an EIM (Equipment
Interface Module).
Yes
Wired Sensors requires an EIM (Equipment
Interface Module).
Yes
Wired Sensors requires an EIM (Equipment
Interface Module).
Select 10K or 20K based on the sensor
installed. Refer to resistance values below:
50062329-001 = 10K ohm
32005180-002 = 10K ohm
C7735A1000 = 10K ohm
C7770A = 20K ohm
C7041 = 20K ohm
Yes
Wired Sensors requires an EIM (Equipment
Interface Module).
Yes
Wired Sensors requires an EIM (Equipment
Interface Module).
Select 10K or 20K based on the sensor
installed. Refer to resistance values below:
50062329-001 = 10K ohm
32005180-002 = 10K ohm
C7735A1000 = 10K ohm
C7770A = 20K ohm
C7041 = 20K ohm
Yes
If an optional Discharge Air Temperature
sensor is used, this feature can help
prevent icing on the air conditioning A-Coil.
When temperature reaches the limit you
set, compressor(s) will shutoff while the
system fan continues to run, until the
temperature rises to a safe level.
®
IAQ WITH EIM
68-0311—02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thx9421 prestige iaq with eim