Honeywell THX9321 Prestige 2.0 Product Data page 66

Hide thumbs Also See for THX9321 Prestige 2.0:
Table of Contents

Advertisement

®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
ISU
Installer Setup
Number
Name
13130
Allow Cool Delta T
Diagnostics when
Indoor
Temperature is
[Indoor
Temperature
13130
Range]
13140
Allow Cool Delta T
Diagnostics when
Indoor Humidity is
[Indoor Humidity
Range]
13140
13150
Allow Cool Delta T
Diagnostics when
Outdoor
Temperature is
[Outdoor
Temperature
13150
Range]
13160
Allow Cool Delta T
Diagnostics when
Outdoor Humidity
is [Outdoor
Humidity Range]
13160
68-0311—02
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Minimum Setting
No Limit
35° F to 115° F (in 5° F
increments)
Maximum Setting
No Limit
40° F to 120° F (in 5° F
increments)
Minimum Setting
No Limit
0% to 95% (in 5% increments)
Maximum Setting
No Limit
5% to 100% (in 5% increments)
Minimum Setting
No Limit
-50° F to 135° F (in 5° F
increments)
Maximum Setting
No Limit
-45° F to 140° F (in 5° F
increments)
Minimum Setting
No Limit
0% to 95% (in 5% increments)
Maximum Setting
No Limit
5% to 100% (in 5% increments)
®
IAQ WITH EIM
Residential,
Commercial
Default
or Both
No Limit
Both
(Always)
No Limit
Both
(Always)
No Limit
Both
(Always)
No Limit
Both
(Always)
No Limit
Both
(Always)
No Limit
Both
(Always)
No Limit
Both
(Always)
No Limit
Both
(Always)
66
Requires
EIM
Notes
Yes
This ISU only applies to Cooling.
This ISU is only displayed when ISU 13015
Set Advanced Diagnostic Options is set to
Yes.
Yes
The thermostat monitors Delta T of the
system ONLY when the indoor temperature
is within a certain range. Set to No Limit to
monitor Delta T during all indoor
temperature conditions.
Yes
This ISU only applies to Cooling.
This ISU is only displayed when ISU 13015
Set Advanced Diagnostic Options is set to
Yes.
Yes
The thermostat monitors Delta T of the
system ONLY when the indoor humidity is
within a certain range. Set to No Limit to
monitor Delta T during all indoor humidity
conditions.
Yes
This ISU only applies to Cooling.
This ISU is only displayed when ISU 13015
Set Advanced Diagnostic Options is set to
Yes.
Yes
The thermostat monitors Delta T of the
system ONLY when the outdoor
temperature is within a certain range. Set
to No Limit to monitor Delta T during all
outdoor temperature conditions.
Yes
This ISU only applies to Cooling.
This ISU is only displayed when ISU 13015
Set Advanced Diagnostic Options is set to
Yes.
Yes
The thermostat monitors Delta T of the
system ONLY when the outdoor humidity is
within a certain range. Set to No Limit to
monitor Delta T during all outdoor humidity
conditions.