Huawei RRU3269 Installation Manual page 125

Hide thumbs Also See for RRU3269:
Table of Contents

Advertisement

RRU3269
Installation Guide
Table 9-2 RRU power cables
Cable
RRU
power
cable
Procedure
Step 1 Connect the female connector (pressfit type) at one end of the RRU power cable to the power
supply socket on the RRU, as shown in Figure 9-29.
Issue Draft B (2018-05-15)
On the RRU
Side
Female
connector
(pressfit type)
Before installing RRU power cables, ensure that the upper-level circuit breaker is
disconnected, and the power cable has no voltage.
A drip loop is required for the position between the RRU port and the cable, preventing
rain from damaging the RRU.
When installing the RRU power cable, connect the power cable to the RRU connector first
and then to the power equipment connector. Incorrect connection sequence or reverse
connection of position and negative poles may damage the RRU or cause personal injury.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
On the
Pow
Power
er
Device Side
Devi
ce
Female
EPU
connector
DCD
(pressfit type)
U-11
B
EPC5
DCD
connector
U-12
B
9 Installing RRU Cables
Color
A cable with a black jacket and
two wires inside
North American standards:
The RTN(+) wire is black and
the NEG(-) wire is blue.
European standards: The
RTN(+) wire is brown and the
NEG(-) wire is blue.
China: The RTN(+) wire is red
and the NEG(-) wire is blue.