Huawei RRU3269 Installation Manual page 103

Hide thumbs Also See for RRU3269:
Table of Contents

Advertisement

RRU3269
Installation Guide
Issue Draft B (2018-05-15)
The operating temperature of fiber optic cables ranges from -40º C to +60º C (-40º F to
+140º F). If the actual temperature is beyond this range, take protective measures or
select another route.
Do not circle and twist cables.
Do not bind a fiber optic cable at the position where it bends.
Do not stretch, step on, or place heavy objects on fiber optic cables. Keep the fiber optic
cables away from sharp objects.
When fiber optic cables are routed, the excess of the fiber optic cables must be coiled
around special devices, such as a fiber coiler.
An unarmored fiber optic cable must be bound using binding straps. If a fiber optic patch
cord needs to be secured in a cabinet or a piece of equipment, use binding straps to bind
it and then use cable ties to secure the binding straps to the cabinet or equipment. Ensure
that the fiber optic cables can flexibly move in the cable ties. Do not bend the fiber optic
cables sharply. The following figure shows how to bind the fiber optic cables correctly.
Figure 9-5 Binding fiber optic cables
When coiling fiber optic cables, apply even strength. Do not bend the fiber optic cables
with force.
Unused optical connectors must be covered with dustproof caps.
The fiber optic cables must not be pressed by the door of the cabinet when routed, as
shown in the following figures.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9 Installing RRU Cables
95

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents