Vermont Castings Encore FlexBurn 2040 Installation & Operating Manual page 5

Non-catalytic/catalytic wood burning stove
Table of Contents

Advertisement

Installation
SAFETY NOTICE: IF YOUR ENCORE
INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE
THE RISK OF FIRE, FOLLOW THE INSTALLATION
INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE
OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION
INSPECTION REQUIREMENTS IN YOUR AREA.
• Your stove and chimney connector will be far enough from
combustible material to meet all clearance requirements.
properly to meet all requirements.
• You have all necessary permits from local authorities.
your installation as safe and determining that it meets local
and state codes.
The metal label permanently attached to the back of every
information also is printed on the label. When the stove is
installed according to the information both on the label and
as evidence that the installation meets codes and can be
approved.
Your local dealer can provide any additional information
needed.
Appliances and Equipment. These standards are the basis for
many national codes. They are nationally recognized and are
accepted by most local authorities. Your local dealer or your
IMPORTANT: Failure to follow these installation
instructions may result in a dangerous situation, including
and do not allow makeshift compromises to endanger
property and personal safety.
5
IS NOT PROPERLY
®
Vermont Castings • Encore® Flexburn Installation Manual_R43 • 11/18
Outside Air
to take place. Whatever combustion air is consumed by the
Items Needed for Installation (not supplied)
• Phillips head screw driver
• Silicone sealant
• Drills and saws necessary for cutting holes through
connect outside air to appliance intake. Use the supplied
termination cap with a rodent screen. Seal between the
penetration.
near the stove will usually alleviate the problem.
A better solution is to install a permanent outside air supply
from outside the home directly to the air inlet of the stove is
required for new construction in some areas.
Types of Chimney to Use
You must connect the Encore
two types. The chimney and chimney connector must be in
good condition and kept clean.
®
3-90-30005295

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents