Vermont Castings Encore FlexBurn 2040 Installation & Operating Manual page 17

Non-catalytic/catalytic wood burning stove
Table of Contents

Advertisement

Mobile Home Installation
1. An outside air inlet must be provided for combustion and
room air starvation which can cause smoke spillage and
set off smoke alarms.
2. The appliance must be secured to the mobile home
3. Stove must be grounded with #8 solid copper grounding
wire or equivalent and terminated at each end with
terminal cap with spark arrestor. Never use a single wall
any listed double wall pipe connector.
5. Refer to the clearance charts in this manual or the serial
number label on the back of the stove for clearances to
combustibles.
6. Floor protection requirements must be followed precisely.
Refer to the "Floor Protection" section in this manual.
Refer to the "Floor Protection" section in this manual.
8. Use silicone to create an effective vapor barrier at
the location where the chimney or other component
9. Follow
the
chimney
system for use in a mobile home.
NOTE:
clearance and termination must be in compliance with the
211.
NOTE: Top sections of the chimney must be removable to
level for transportation purposes.
17
and
chimney
connector
Vermont Castings • Encore® Flexburn Installation Manual_R43 • 11/18
!
NEVER DRAW COMBUSTIBLE AIR FROM A
WALL, FLOOR OR CEILING CAVITY OR FORM
ANY ENCLOSED SPACE SUCH AS AN ATTIC OR
GARAGE.
!
THE STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALL AND CEILING/ROOF MUST BE
MAINTAINED. (i.e., DO NOT CUT THROUGH FLOOR
JOIST, WALL STUD, CEILING TRUSS, etc.).
!
DO NOT INSTALL IN SLEEPING ROOM
Firestop
Floor
Protection
Figure 18
WARNING
CAUTION
WARNING
Spark
Roof
Flashing
3-90-30005295