Advertisement

Quick Links

Installation instructions and user guide
Zip
HydroChill
Model HC05T120
Installation instructions & user guide
1
T210055 HC05T120 installation instructions & user guide v1.00 May 2022

Advertisement

Table of Contents
loading

Summary of Contents for Zip HydroChill HC05T120

  • Page 1 Installation instructions and user guide HydroChill Model HC05T120 Installation instructions & user guide T210055 HC05T120 installation instructions & user guide v1.00 May 2022...
  • Page 2: Table Of Contents

    Table of contents SECTION 1 Using these instructions ..............3 Before you start ....................3 Explanation of symbols ..................3 Introduction ...................... 3 SECTION 2 IMPORTANT SAFETY INSTRUCTIONS ..........4 SECTION 3 WARNINGS & REGULATORY INFORMATION ........5 SECTION 4 Technical data ................. 7 4.1 Technical data table..................
  • Page 3: Section 1 Using These Instructions

    • Your new appliance is designed to give you years of trouble-free service provided that the instructions contained in this manual are followed. • All new Zip products are energy efficient, simple to operate and easy to service. • Find out more about Zip products at www.zipwater.co.uk.
  • Page 4: Section 2 Important Safety Instructions

    SECTION 2 IMPORTANT SAFETY INSTRUCTIONS Compliance In the UK the appliance must be installed in accordance with water supply byelaws, current IEEE regulations and local authority byelaws. Safety This appliance is not intended for use by children under 8 years or persons (including children under 8 years) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by...
  • Page 5: Section 3 Warnings & Regulatory Information

    When positioning the appliance, ensure the power supply cord is not trapped or damaged. If it is damaged it must be replaced by a Zip service provider or a qualified electrician. Installation instructions & user guide T210055 HC05T120 installation instructions & user guide v1.00 May 2022...
  • Page 6 • Zip cannot be held responsible for any appliance malfunction if the water pressure exceeds that stated. If in doubt, consult your water supply company.
  • Page 7: Section 4 Technical Data

    SECTION 4 Technical data 4.1 Technical data table HC05T120 Model Unit Width Depth Height 1237 (inc tap) Cooling system Direct cooling tank Cooling type Force ventilation Cooling capacity L/hr Supply voltage V AC Single phase 230V 50Hz Power rating 0.185 Water temperature 5 - 12 Working temperature range...
  • Page 8: Section 5 Parts Supplied

    10mm x 5/8" Pozi Screw 3/4" BSP - 1/4" Push fit connector 1/4"- 5/16" Straight connector Micropurity filter for chillers ,3 micron Zip Filter Head side outlet external 5.2 Filter identification • The filter is identified on its front label.
  • Page 9: Section 6 Installing The Appliance

    SECTION 6 Installing the appliance 6.1 Positioning and ventilation Use of tools can be hazardous, assess the risks before you start. If the appliance has been shipped horizontally or on an angle, stand upright and allow 8 hours before the electricity supply is connected. Use instructions supplied with individual kit parts.
  • Page 10 SECTION 6 Installing the appliance 6.1.2 Installation layout and features Mains water supply Bubbler Isolation valve (install rail) Dispensing tap Font waste pipe (flexible drain Water block hose) 3/4" BSP - 1/4" adapter Waste to drain 1/4" plastic pipe Mains electricity supply Filter &...
  • Page 11: Attach The Tap Spout And Lever

    SECTION 6 Installing the appliance 6.2 Attach the tap spout and lever • Locate the tap lever and clip onto Tap lever the tap body. Tap body • Screw the tap spout into the tap body, and secure with the screw on Tap spout the back of the tap body.
  • Page 12: Connect The Appliance Font To Waste

    SECTION 6 Installing the appliance 6.3 Connect the appliance font to waste IMPORTANT drain pipework must be no less than 15 mm diameter. Font Font drain Worm drive connection clamp Flexible drain hose • Locate the font drain connection at Flexible drain the rear of the appliance.
  • Page 13: Push Fit Best Practice

    If the mains water pressure exceeds 3 bar a suitable water pressure reducing valve must be fitted. Zip cannot be held responsible for any appliance malfunction if the water pressure is not within the range stated. If in doubt, consult your water supply company.
  • Page 14 SECTION 6 Installing the appliance 6.5.1 Mains water connection (Using the filter, install rail & Water block) Use instructions supplied with the individual system components. • Water purification filters ensure fresh tasting water. • The Water Block limits the amount of water flowing to a predetermined flow rate, lowering the 15mm mains water risk of harm to people...
  • Page 15 SECTION 6 Installing the appliance 6.5.2 Water block This device must be installed vertically with Fig. 1 the direction of flow downwards (inlet at the top, outlet at the bottom). See Fig. 1. • The Water block should be installed in a convenient location on the water supply line to the appliance.
  • Page 16: Connect The Electricity Supply

    SECTION 6 Installing the appliance 6.6 Connect the electricity supply Before you start, read : SECTION 2 IMPORTANT SAFETY INSTRUCTIONS. SECTION 3 WARNINGS & REGULATORY INFORMATION. Do not switch on the mains electricity supply until installation is complete, The system earth must be verified once the mains electricity supply connection has been established.
  • Page 17: Earth Continuity Test

    SECTION 6 Installing the appliance 6.7 Earth continuity test All accessible metal parts must be earthed. One probe connected One probe to the mains cable • Before installation, the earth connected earth wire / pin continuity must be checked. to chassis Use an insulation tester, appliance tester , DMM or continuity tester with an...
  • Page 18: Section 7 Commissioning And Operation

    • Switch on the mains power supply. • All HydroChill models must be sanitised during the commission process, please contact Zip on 0345 6 005 005 to book a commissioning service. • If your appliance is left idle before use,...
  • Page 19: Operation

    SECTION 7 Commissioning and operation 7.2 Operation • Wait 20mins for the appliance to reach the correct temperature. • Press the tap lever to manually dispense water from the tap. • Press the button on top of the bubbler to manually dispense water from the bubbler.
  • Page 20: Section 8 Maintenance

    SECTION 8 Maintenance 8.1 Replace and flush the filter 8.1.1 How to replace and flush the filter Insert Remove • Turn off the mains water supply isolation valve. • Turn off the electrical power supply to the appliance. • Remove the old filter (see above). Water may drip from the filter head. •...
  • Page 21: Cleaning

    SECTION 8 Maintenance 8.2 Cleaning Do not use air-drying disinfectant sprays. Do not use abrasive cleaning agents to clean the appliance. The appliance must never be located near or cleaned with water jets. • To clean the appliance and tap, wipe surfaces with a damp cloth and then wipe dry with a clean, dry cloth.
  • Page 22: Environmental Information

    Environmental information Waste electrical and electronic equipment • The symbol above means that according to United Kingdom and European Union member countries laws and regulations, your product and / or its battery shall be disposed of separately from household waste. •...
  • Page 23: Warranty

    • Subject to the exclusions set out below and in Clause 5 of the Terms and Conditions, faulty parts and products will be replaced or repaired free of charge by Zip, or its Distributor or Service Provider in respect of those Goods and Services where such fault arises during the applicable Warranty Period.
  • Page 24 Zip Water Trafalgar House, Rash’s Green, Dereham, Norfolk, NR19 1JG 0345 6 005 005 sales@zipindustries.co.uk specify.zipwater.co.uk Installation instructions & user guide T210055 HC05T120 installation instructions & user guide v1.00 May 2022...

Table of Contents