ote:
To compensate for changes in actual air flow versus calculated,
provide adjustable profile plates so that final settings can be
made in the field. Figure 3.6 shows an example of an adjustable
profile plate design.
djustable Profile Plates
igure 3.6
AH-MA
Burner
Adjustable
Profile Plate
Profile Plate
Side View
igure 3.7
rofile late ositioning
Profile
Plate
¼ to 1"
AH-MA
Burner
Profile
Plate
clipse AH-MA Air Heat Burner v2, Design Guide 160, 8/1/05
Elongated Screw Slots
Fixed
Duct
Wall
Front View
Caution:
Profiles plate should be positioned
upstream of the firing end of the
burner. If necessary, the plates can be
located up to 1" back from the firing
end, but under no circumstances should
they be in front of the burner.