Download Print this page

Eclipse AH-MA Series Design Manual page 15

Airheat burners

Advertisement

izing and layout of the gas manifold
hoose the gas manifold size to evenly supply gas to each of the
sections, using Table 3.3 and Figure 3.2.
Gas Pipe Sizing & Layout
able 3.3
AXI U
ANIFOLD
GAS INPUT
PIPE SIZE
( BTU/HR.)
(INCHES)
1.4
2.5
5.2
8.0
14.0
45.0
80.0
ote:
Maximum inputs shown for natural gas only. For propane,
multiply inputs by 1.5; for butane, multiply inputs by 1.7.
igure 3.2
Gas Manifold izing & Layout
Main
Pipe
Union
Gas
Gas Manifold
Pipe
Union
Pilot End Plate
Spark
Ignitor
Pilot
Gas
Flame
Rod
xample: A gas manifold is supplying gas to two 1-1/2" N.P.T. rear
inlets on a burner. ach of the rear inlets supplies a maximum of
2,000,000 Btu/hr.
Solution: The total fuel supplied is 2 x 2,000,000 = 4,000,000 Btu/hr.
Referring to Table 3.3, the choice for manifold size is 2-1/2"; the
choice for main gas pipe size is 2".
clipse AH-MA Air Heat Burner v2, Design Guide 160, 8/1/05
AXI U
GAS INPUT
( BTU/HR.)
1-1/2
0.3
2
0.6
2-1/2
1.1
3
3.2
4
6.6
6
13.0
8
20.0
Pipe
Union
Burner Body
AIN GAS
PIPE SIZE
(INCHES)
1/2
3/4
1
1-1/2
2
2-1/2
3
Burner
Feed Pipe
Plain
End Plate

Advertisement