Maintenance - Intec FORCE/2 HP Instruction Manual

Insulation blowing machine
Hide thumbs Also See for FORCE/2 HP:
Table of Contents

Advertisement

Instruction Manual
|
12

Maintenance

Preventative maintenance will provide for many years of trouble-free use.
Cleaning
Clean the interior and exterior of the machine weekly by wiping with a rag and/or blowing with
compressed air; this will help maintain the longevity of the mechanical components in addition to the
system's finish. The machine has been designed to work in a dusty environment. However, without
periodic cleaning and maintenance, the performance of the machine will decline potentially leading to
failure.
Cords
Your 12 gauge power cords are subject to considerable wear and tear during normal operation. Inspect
all cords prior to use to ensure safe operation. If any damage is observed, be sure to repair or replace
before operating the machine to avoid personal injury. Note: Do not pull on power cords while
plugged into machine as damage may occur.
Airlock and Seals
The airlock assembly is one of the most important items to keep in good condition. Foreign objects in
the airlock can cause damage and reduce the machine's production. Seal failure is the most common
airlock assembly failure. Seal failure prevents the airlock from holding the proper pressure. Seal
failure will reduce the machine's production. A machine with seal failure will have air blow out of the
airlock into the hopper, reducing the amount of air exiting the machine outlet. It is recommended to
visually inspected seals each week to ensure proper running condition. Replace airlock seals if a cut or
tear is evident. Airlock seals should be replaced approximately every 300 hours of operation, or once
per year. Visit www.inteccorp.com or contact Intec for replacement instructions.
Gearbox
It is recommended to change the gearbox oil once per year. When changing the oil be sure to use the
correct lubricant. In operating temperatures between 40 to 100 degrees Fahrenheit, use Mobil SHC
634 gear lube. In temperatures below 40 degrees, use Mobil 1 synthetic 5W-30.
Blower Brushes
Blower brushes will need to be replaced periodically -- 500 to 600 hours is a typical life.
T: 303-833-6644
800-666-1611
www.inteccorp.com