Nova-243 Outdoor LTE TDD Base Station Installation Guide
The Nova-243 interfaces are described in Table 1-1.
Interface Name
ETH0
ETH1
SNF
ANT0
ANT1
GPS
PWR
The Nova-243 interface indicators are described in Table 1-2.
Identity
Color
RUN
Green
ALM
Red
ACT
Green
VSWR
Red
1.4

Technical Specification

1.4.1 Hardware Specification

Item
LTE Mode
LTE Bands
Table 1-1 Nova-243
RJ-45
electronic
self-adaptation, external transmission network.
RJ-45 electric interface, used for debugging.
External Sniffer, Type N interface
External antenna 1,Type N interface
External antenna 2,Type N interface
External GPS antenna, Type N interface
Power interface: -48V DC (-36V~-60V)
Table 1-2 Nova-243
Status
Fast flash: 0.125s
on,0.125s off
Slow flash: 1s on,1s off The board is normal.
OFF
Steady On
OFF
Steady On
OFF
OFF
Steady On
LTE TDD
BRU3501: 3650MHz~3700MHz for FCC application
3550MHz~3700MHz for IC application
BRU3508: 2300MHz~2370MHz
BRU3509: 2300MHz~2320MHz
Interface Description
Description
interface,
support
Interface Indicators
Description
The board is loading.
No power input or board fault
Hardware alarm, e.g. VSWR alarm
No alarm
The cell has been activated.
The cell has not been activated.
The standing wave is normal.
The standing wave is large than
normal.