Patient Monitor – Patient Monitor Interface – Importing and Adding Media Files – The Laerdal Debrief Viewer – The Laerdal Advanced Video System (AVS) – Customizing Scenarios – Turning the Internal Compressor Off – Changing Settings During Simulation – Changing Default Settings –...
For technical assistance, contact your local Laerdal Technical Service such training devices, there may be approximations, variations and Center. inaccuracies in anatomical features and the physiological modeling. This being the case, Laerdal does not guarantee that all features are completely accurate. Web Downloads Global Warranty Visit http://www.laerdal.com to download the latest Directions for...
Page 5
Staining may be permanent. – Never use the SimJunior manikin outdoors in wet conditions, as this may pose a shock hazard or damage the manikin. – Clean manikin skins with mild soap and water.
Page 6
Do not defibrillate the manikin if the torso skin is not in place. – The SimJunior manikin and accessories are heavy when combined in the carrying case. Always ensure that SimJunior is firmly secured during transportation and storage to prevent personal injury or Mechanical or Electrical Hazards damage to the product.
Page 7
Introduction SimJunior Simulator Right Arm ECG Left Arm ECG Connector Connector Sternum Defib Plate Blood Pressure Apex Defib Plate IV Arm Right Leg ECG Left Leg ECG Connector Connector Power Cable External Air Connection 37 Pin Serial Cable (Manikin to Manikin Cable...
Page 8
. r o SimJunior allows observation and recognition of most vital signs, which Prior to using airway devices, lubricate with Laerdal Airway Lubricant. enables the instructor to assess the student’s skills based on a realistic clinical situation.
Page 9
– Peripheral veins of the forearm. Defibrillation Studs – Antecubital fossa and dorsum of the hand. For use of an optional catheter, see your local Laerdal representative. Intraosseous Access (IO): Access for IO infusion is possible: – Tibial Tuberosity (right) –...
Standard System Setup Summary See below illustration “Setup of SimJunior Standard. ” Connect the SimPad to the Link Box – Connect the Link Box to power supply or battery. – The SimPad can connect to the Link Box wirelessly or wired with a Network Cable.
SimPad Link Box and Accessories power ON. – Operating Software for the SimPad System – Make sure that the SimJunior simulator icon is displayed on the – Instructor Laptop PC Instructor PC desktop – Operating Software for the Instructor PC 2.
7. Calibrate the Touchscreen Patient Monitor. Instructor Software License – Double-click on the Elo logo in the system tray in the lower Instructor PC is shipped from Laerdal Medical with a pre-activated right corner of the screen. license installed. –...
Page 13
Advanced System 1. Program Menu Bar 7. Debrief Log 2. Respiratory Control 8. Trend and Handler Control 3. Simulator Sounds, Airway, and Circulation 9. Running Trends 4. Defibrilation and Pacing Control 10. Trend Window 5. Instructor Monitor Control 11. Running Handlers 6.
Save the Debrief Log to archive and/or review later. Click <Debrief> changes, select Trends or Handlers, and start or stop both Trends to start the Debrief Viewer. For more information, see The Laerdal and Handlers. Debrief Viewer section of this manual.
Advanced System 2. Parameters Readout Area Select the <Media> button to open display. Select the <Close> button to close the Media display. The learner may also edit scaling, alarm limits, etc. using this interface. Clicking the parameter of interest will present a menu with available options.
Customizing Scenarios 1. Ensure that the main menu is displayed. 2. Click on the appropriate Radiology, Media, or Labs button. SimJunior scenarios can be created and edited using a set of editors: 3. Click <Order New> in the dialog box. •...
Click the < Seizure intensity > option. The Internal Compressor, Tongue Edema, and Seizure can be adjusted during the simulation by accessing the SimJunior Dialog Menu. Any changes made in this window will not effect the default settings of the manikin.
Preparing for Simulations 2. Open the plug at the heel. After the SimJunior manikin is prepared and all applicable interactive units (SimPad or Instructor PC and Patient Monitor) are 3. With a syringe, fill the bone with approximately 240 to 250 cc of configured and made ready for use, final preparations may need to be...
During Defibrillation A conventional defibrillator (not included) may be used on the SimJunior. During live defibrillation, the defibrillator and manikin may present a shock hazard. All standard safety precautions must be taken when using the defibrillator on the manikin.
. s e A separate kit containing plastic pupil inserts (constricted and dilated) comes with SimJunior. To change the pupils: 1. Carefully open the eyelids wide, taking care not to tear the manikin face skin.
Maintenance Maintenance After Each Simulation Session The following preventive measures are required to ensure longevity of the SimJunior manikin. − Return manikin and PC to their original condition. – Power off the SimPad, Link Box and PCs. – Charge batteries if necessary.
Note: DO NOT s e l i t c 5. Replace the charged battery or install a new Laerdal approved the stomach foam to the manikin. SimJunior battery. 5. Replace the torso skin by performing steps 1- 4 in reverse.
Maintenance Charging the Manikin Battery The manikin battery charges itself as it is operated. If necessary, the manikin battery can be charged using an optional external power adapter. 1. Power down the manikin via the Link Box. 2. Remove the manikin battery from the manikin. 3.
Maintenance Replacing Manikin Skins To attach the new arm: The manikin skins may need to be replaced if they are torn, perforated, or stained. Torso Skin: To replace the manikin torso skin reference “Opening the Torso” section Arm Skin: To replace the manikin arm skin: 1.
Possible Solution • Should system shutdown or all data is lost or corrupted; please contact your local Laerdal Service Center. • Clean the outside of the manikin with manikin wipes. Clean the inside of the oral cavity with manikin wipes. Change the lung bladder;...
Page 26
Solution 1. Power off the Link Box. 2. Turn the SimPad off. 3. Exit any SimJunior software on the optional Instructor PC and the Patient Monitor. 4. Then restart everything. If the manikin is still unresponsive, contact your Laerdal representative.
Mild solution of liquid soap and water Internal battery: 7.4V, 4.4Ah, Lithium-Ion IV Fluids Only use approved SimJunior external power supply and batteries. Only use distilled or deionized water to simulate IV and IO Air Pressure fluids. Internal air tank:...
Spare Parts and Accessories Catalogue Numbers Substitute XX with your local language version number. Contact your local Laerdal Customer Service Representative for more information. 231-01150 Pediatric Full Body Soft Case 232-05350 SimJunior Hard Case 210-05250 Peripherals Hard Case 5527 Laerdal Warranty 232-11950 SimJunior Advanced SW CD &...