DIAGNOSTIC SELF-TEST
On initial installation or for troubleshooting, run a diagnostic test for data about
the firmware version, emulation, code page, sensor and interface settings, and so
forth�
Note: If you do not find any issues during the test, examine other devices and
software to resolve any issues.
To run a diagnostic self test
1�
Turn off the printer�
2�
Press and hold both the Feed and Power buttons at the same time� The
informational label prints�
3�
For Hex dump mode, press the Feed button after steps 1 and 2� Once the
ASCII pattern prints, the diagnostic test is complete�
Note: Printer terminates the test mode after 3 seconds, if the Feed button is not
pressed for Hex mode.
Note: To prevent the moter
from overheating, stop
the printer for at least 30
seconds after printing 1.5
meters continuously.