Ring/Network Coupling
Note: The following settings are required for the coupling ports (you
select the Basic Settings:Port Configuration dialog):
See table on
Note: If VLANs are configured, set the coupling and partner coupling
ports' VLAN configuration as follows:
– in the dialog Switching:VLAN:Port Port VLAN ID 1 and „Ingress
Filtering" deactivated
– in the dialog Switching:VLAN:Static VLAN-Membership U
(Untagged)
 Select "Two-Switch coupling with control line" by means of the dialog
button with the same graphic as below
3
2
STAND-BY
Figure 24: Two-Switch coupling with control line
1: Coupling port
2: Partner coupling port
3: Control line
The following settings apply to the switch displayed in blue in the
selected graphic.
 Select the coupling port
With "Coupling port" you specify at which port you are connecting
the network segments:
You will find the port assignment for the redundant coupling in
table 10.
 For a device with DIP switches, you switch the stand-by switch to ON
or deactivate the DIP switches. You connect the redundant line to
the coupling port.
 Select the control port
With "Control port" you specify at which port you are connecting the
control line.
UM Redundancy Configuration L2E
Release 7.1 12/2011
17 "Port settings for ring
1
ON
(see fig.
(see fig. 23)
4.2 Preparing a Ring/Network
ports".
(see fig.
24).
23).
Coupling
53