Ring/Network Coupling
Device
RS2-./.
RS2-16M
RS20, RS30, RS40
OCTOPUS
MICE
PowerMICE
MS20
MS30
RSR20/30
MACH 100
MACH 1000
MACH 3000
MACH 4000
Table 9: Port assignment for the redundant coupling (two-Switch coupling)
Note: Configure the coupling port and the redundancy ring ports on different
ports.
 Activate the function in the "Operation" frame
 Now connect the redundant line.
The displays in the "Select port" frame mean:
– "Port mode": The port is either active or in stand-by mode.
– "Port state": The port is either connected or not connected.
– "IP Address": The IP address of the partner, if the partner is already
operating in the network.
The displays in the "Information" frame mean:
– "Redundancy guaranteed": If the main line no longer functions, the
redundant line takes over the function of the main line.
– "Configuration failure": The function is incomplete or incorrectly
configured.
UM Redundancy Configuration L2E
Release 7.1 12/2011
Coupling port
Not possible
Adjustable for all ports (default setting: port 1)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 2.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 2.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports
Adjustable for all ports (default setting: port 1.4)
4.2 Preparing a Ring/Network
(see fig. 16)
Coupling