Ring/Network Coupling
Device
RS2-./.
RS2-16M
RS20, RS30, RS40
OCTOPUS
MICE
PowerMICE
MS20
MS30
RSR20/30
MACH 100
MACH 1000
MACH 3000
MACH 4000
Table 9: Port assignment for the redundant coupling (two-Switch coupling)
Note: Configure the coupling port and the redundancy ring ports on different
ports.
Activate the function in the "Operation" frame
Now connect the redundant line.
The displays in the "Select port" frame mean:
– "Port mode": The port is either active or in stand-by mode.
– "Port state": The port is either connected or not connected.
– "IP Address": The IP address of the partner, if the partner is already
operating in the network.
The displays in the "Information" frame mean:
– "Redundancy guaranteed": If the main line no longer functions, the
redundant line takes over the function of the main line.
– "Configuration failure": The function is incomplete or incorrectly
configured.
UM Redundancy Configuration L2E
Release 7.1 12/2011
Coupling port
Not possible
Adjustable for all ports (default setting: port 1)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 2.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports (default setting: port 2.4)
Adjustable for all ports (default setting: port 1.4)
Adjustable for all ports
Adjustable for all ports (default setting: port 1.4)
4.2 Preparing a Ring/Network
(see fig. 16)
Coupling
43