Ring Redundancy
2.1.1

Setting up and configuring the HIPER-Ring

 Set up the network to meet your demands.
 Configure all ports so that the transmission speed and the duplex settings
of the lines correspond to the following table:
Port type Bit rate
TX
100 Mbit/s
TX
1 Gbit/s
Optical
100 Mbit/s
Optical
1 Gbit/s
Optical
10 Gbit/s
Table 3: Port settings for ring ports
Note: When activating the HIPER-Ring function via software or DIP
switches, the device sets the corresponding settings for the pre-defined ring
ports in the configuration table (transmission rate and mode). If you switch off
the HIPER-Ring function, the ports, which are changed back into normal
ports, keep the ring port settings. Independently of the DIP switch setting, you
can still change the port settings via the software.
 Select the Redundancy:Ring Redundancy dialog.
 Under "Version", select HIPER-Ring.
 Define the desired ring ports 1 and 2 by making the corresponding
entries in the module and port fields. If it is not possible to enter a
module, then there is only one module in the device that is taken
over as a default.
UM Redundancy Configuration L2E
Release 7.1 12/2011
Autonegotiation
Port setting
(automatic
configuration)
off
on
on
on
off
on
on
on
-
on
2.1 Example of a HIPER-Ring
Duplex
100 Mbit/s full duplex (FDX)
-
100 Mbit/s full duplex (FDX)
-
10 Gbit/s full duplex (FDX)
17