Circulation Pump And Motor; Wash Cycles - GE PDW9200 Series Technical Service Manual

Top control profile dishwashers
Hide thumbs Also See for PDW9200 Series:
Table of Contents

Advertisement

Wash Cycles

MAX # OF
WASH
CYCLE
PRE-WASH
CYCLE
CYCLES
Normal Wash
3
1
Speed Wash
3
1
Glasses
3
1
China Crystal
3
1
Pots & Pans
4
1
Sani Wash
3
1
Rinse Only
0
0
Plastics
3
1
Time is in minutes
Temperature is in degrees Fahrenheit
1.) Cycle times do not include water fill and drain
2.) Heater on in main wash and final rinse
3.) Heater on in all pre-washes, main wash and all rinses
4.) 8 minutes heated dry and 15 minutes cool down
5.) 45 minutes without heated dry, 60 minutes with heated dry
6.) Fan running time after cycle has completed

Circulation Pump and Motor

The dishwasher must be removed from its
in stal la tion to gain access to the circulation pump
and motor. The circulation pump can be activated
using
. Refer to sche mat ic or strip
Service Mode
circuit for motor resistance value.
Before removing the circulation pump, remove
the water from the sump with a syringe.
It is important to remember the motor does not
start immediately when the dishwasher cycle has
started. If the motor hums, but will not start, make
certain the pump impeller is free from obstruction
and the motor shaft can turn freely.
The terminals on the induction motor are labeled
L1 and N. The motor is thermally protected
(internally) through the L1 side. The wiring
connector is blue to match the wire leading to
the motor. It is designed to fi t only one way on
the terminals. Make certain the connector is fully
seated when installing.
Note: It is extremely important that the self-
tapping grounding screw is tightened securely
when reinstalling the circulation pump.
MAX #
1
WASH TEMPERATURE
WASH TIME
RINSE
MIN
MAX
CYCLES
3
32
88
2
19
26
3
26
39
3
30
52
3
44
108
3
21
100
2
2
2
3
39
88
– 13 –
HEATED
DRY TIME
MIN
MAX
2
2
38
130
150
3
3
8
125
150
3
3
30
110
130
3
3
30
110
130
3
3
38
140
150
3
3
4
130
158
8+15
80
158
Not An Option Not An Option
2
2
5
130
140
45/60
Circulation Pump and Motor Strip Circuit
6
FAN ON TIME
HEATED DRY W/O HEATED DRY
120
240
120
240
120
240
120
240
120
240
120
240
240
120
240
Screw