Table 2- 22 Message Texts (Printer Driver) - Siemens Simatic S7-300 CP 341 User Manual

Point-to-point communication, installation and parameter assignment
Table of Contents

Advertisement

Basic Principles of Serial Data Transmission
2.8 Configuration data
Message texts
The table below contains a description of the parameters for configuring message texts
(using the CP 341: Point-to-Point Communication, Parameter Assignment parameter
assignment interface).
Table 2- 22
Message texts (printer driver)
Parameters
Name of text SDB/text file
Version number
Message texts
Edit message
Font style
98
www.gkbpx.com
Description
The message texts for a CP 341
(serial interface) must be saved to a
text SDB for parameter assignment.
You can also store configured
message texts in an external text file.
Version number of the text SDB/text
file
All the message texts stored in the text
block are displayed here together with
their message text numbers; you can
change a selected message text line
by means of the "Edit Message"
parameter.
You can transfer message texts edited
here to the "Message Texts" list by
clicking the "Enter" button.
You can easily assign control
characters to text selected in the "Edit
Message" entry box by using buttons B
to U.
CP 341 Point-to-Point Communication, Installation and Parameter Assignment
Range of values
ASCII characters (max. 8
characters)
1 to 255.9
ASCII characters (unchangeable)
Message number:
0 to 1999
Message text (max. 150
characters):
ASCII characters (text)
Conversion statements (for
variables)
Control characters (all those
defined in the control character
table)
B (bold)
C (condensed)
E (expanded)
I (italic)
U (underlined)
Manual, 09/2008, A5E02191071-01