Table 2- 6 Baud Rate/Character Frame (3964(R) Procedure) - Siemens Simatic S7-300 CP 341 User Manual

Point-to-point communication, installation and parameter assignment
Table of Contents

Advertisement

Basic Principles of Serial Data Transmission
2.8 Configuration data
Baud rate/Character frame
The table below describes the baud rate/character frame.
Table 2- 6
Baud rate/Character frame (3964(R) procedure)
Parameters Description
Baud rate
Data transmission rate in bps (baud)
Note:
A maximum of 19200 baud is possible for the 20mA-TTY
interface.
Start bit
During transmission, a start bit is prefixed to each character to be
sent.
Data bits
Number of bits to which a character is mapped.
Stop bits
During transmission, the stop bits are appended to every
character to be sent; this signals the end of a character.
Parity
A sequence of information bits can be extended to include
another bit, the parity bit. The addition of its value ("0" or "1")
brings the value of all the bits up to a defined state. This improves
data integrity.
"No" parity means that no parity bit is sent.
Priority
A partner has high priority if its send request takes precedence
over the other partner's send request. A partner has low priority if
its send request has to wait until the other partner's send request
has been dealt with. With the 3964(R) procedure, you must
configure both communication partners with different priorities,
i.e., one partner is assigned high priority, the other low.
82
www.gkbpx.com
CP 341 Point-to-Point Communication, Installation and Parameter Assignment
Range of values
Default value
300
9600
600
1200
2400
4800
9600
19200
38400
57600
76800
115200
1 (fixed value)
1
7
8
8
1
1
2
None
Even
Odd
Even
Low
High
High
Manual, 09/2008, A5E02191071-01
该文档是极速PDF编辑器生成,
如果想去掉该提示,请访问并下载:
http://www.jisupdfeditor.com/