Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC emission class
(in accordance with EN/IEC 60974-10)
Dimensions L x W x H (with handle)
Weight
Mark of conformity
TransTig 2200
Mains voltage
Mains voltage tolerance
Mains frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% d.c.
Cos phi
Welding current range
Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
10 min/40 °C (104 °F) 40% d.c.
10 min/40 °C (104 °F) 45% d.c.
10 min/40 °C (104 °F) 60% d.c.
10 min/40 °C (104 °F) 100% d.c.
TIG
Electrode
)
p
1)
TIG
Electrode
10 min/25 °C (77 °F) 50% d.c.
10 min/25 °C (77 °F) 60% d.c.
10 min/25 °C (77 °F) 100% d.c.
10 min/40 °C (104 °F) 40% d.c.
10 min/40 °C (104 °F) 60% d.c.
10 min/40 °C (104 °F) 100% d.c.
TIG
Electrode
)
p
MW 4000 MV
2)
-
2)
400 A
2)
360 A
2)
300 A
90 V
10.1 - 26.0 V
20.4 - 36.0 V
9.5 kV
IP 23
AF
F
A
625 / 290 / 705 mm
24.6 / 11.4 / 27.8 in.
60 kg
132.30 lb.
S, CE, CSA
2)
)
2)
2)
2)
2)
2)
2)
MW 5000 MV
500 A
-
440 A
350 A
90 V
10.1 - 30.0 V
20.4 - 37.6 V
9.5 kV
IP 23
AF
F
A
625 / 290 / 705 mm
24.6 / 11.4 / 27.8 in.
60 kg
132.30 lb.
S, CE, CSA
230 V
-20 % / +15 %
50/60 Hz
16 A
No restrictions
3.0 kVA
0,99
3 - 220 A
10 - 180 A
220 A
200 A
170 A
220 A
180 A
150 A
84 V
10.1 - 18.8 V
20.4 - 27.2 V
9.5 kV
103