MagicWave
2500 / 3000
Mains voltage
Mains voltage tolerance
Mains frequency
Mains fuse protection (slow-blow)
Mains connection
Primary continuous power (100% d.c.
Cos phi
Welding current range
Welding current at
Open circuit voltage
Working voltage
Striking voltage (U
The arc striking voltage is suitable for manual operation.
Degree of protection
Type of cooling
Insulation class
EMC emission class
(in accordance with EN/IEC 60974-10)
Dimensions L x W x H (with handle)
Weight
Mark of conformity
MagicWave
2500 / 3000 MV
Mains voltage
Mains voltage tolerance
Mains frequency
Mains fuse protection (slow-blow)
Mains connection
100
1)
TIG
Electrode
10 min/40 °C (104 °F) 35% d.c.
10 min/40 °C (104 °F) 40% d.c.
10 min/40 °C (104 °F) 100% d.c.
TIG
Electrode
)
p
3 x 400 - 460 V
3 x 200 - 240 V
1 x 200 - 240 V
1)
MW 2500
3 x 400 V
± 15 %
50/60 Hz
16 A
3)
Z
at PCC
max
= 122 mOhm
2)
)
4.7 kVA
0,99
3 - 250 A
10 - 250 A
2)
-
2)
250 A
2)
180 A
89 V
10.1 - 20.0 V
20.4 - 30.0 V
10 kV
IP 23
AF
B
A
560 / 250 / 435 mm
22.0 / 9.8 / 17.1 in.
26.6 kg
58.64 lb.
S, CE
MW 2500 MV
3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
± 10 %
50/60 Hz
16 A
32 A
32 A
3)
Z
at PCC
max
= 122 mOhm
MW 3000
3 x 400 V
± 15 %
50/60 Hz
16 A
3)
Z
at PCC
max
= 87 mOhm
5.5 kVA
0,99
3 - 300 A
10 - 300 A
300 A
-
200 A
89 V
10.1 - 22.0 V
20.4 - 32.0 V
10 kV
IP 23
AF
B
A
560 / 250 / 435 mm
22.0 / 9.8 / 17.1 in.
28.1 kg
61.95 lb.
S, CE
MW 3000 MV
3 x 200 - 240 V
3 x 400 - 460 V
1 x 200 - 240 V
± 10 %
50/60 Hz
16 A
32 A
32 A
3)
Z
at PCC
max
= 87 mOhm