Download Print this page

Removal Of Pcbs - Daikin FVXS25FV1B Service Manual

Removal procedure. 2.5/3.5/5.0 kw class
Hide thumbs Also See for FVXS25FV1B:

Advertisement

Si061061

4. Removal of PCBs

Procedure
Step
1. Remove the shield plate.
1
Unfasten the 8 hooks
of the shield plate and
remove it.
2. Remove the sensor PCB.
1
Unfasten the 2 hooks
of the sensor PCB.
2
Disconnect the
connector [S49] and
remove the sensor
PCB.
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Hook
Sensor
PCB
Hook
Shield plate
Hook
(R14751)
Hook
(R14752)
[S49]
(R6789)
Removal of PCBs
Points
9

Hide quick links: