Contact I/O Circuit; Contact Output Circuit - YASKAWA JANCD-YEW01-E Instructions Manual

Interface board for welding power source
Table of Contents

Advertisement

167646-1CD
Interface Board for Welding
Power Supply
7

Contact I/O Circuit

7.1
7
Contact I/O Circuit

7.1 Contact Output Circuit

Contact Output Circuit
Five contact output circuits (4 welding power source specific outputs
(arc-ON, wire inching, wire retract inching, starting point detection
command (optional function)), and 1 universal output) are available
.
Number of outputs and
application
Output method
Insulation method
Output current per point
Number of commons
Active level
Output protection type
1 This is a maximum value in the case of the resistive load. Maximum rate
differs depending on the type of the load (AC/DC, resistive/inductive/capacity
load). Relay contact sticking, and open-close life reduction may occur. When
connecting the inductive load, install elements such as flywheel diode on the
load side. In the case of using I/O current (+24 VU), maximum of approx.
500 mA can be taken out (fuses F1, F2 may blow out when the current
exceeds the above limit).
7-1
5 outputs
ARCON
WIRINCH
WIRRTR
SEARCH
OUT
Relay contact output
Insulation by photocoupler
1)
0.5A (DC, AC, 250 V)
No common connection.
Independent for each output.
0 output = "Contact ON", 1 output = "Contact OFF"
JIS B3501, Output with no protection
HW1481264
Stick start command
(Refer to the note 1)
Wire inching command
Wire retract command
Starting point detection
General output
35 of 40

Advertisement

Table of Contents
loading

Table of Contents