Device Net - Slave I/O
4
Supported Devices
Input Area Size (word)
Output Area Size (word)
DIO Start Address
*1 Though the Input /Output area size can be set from 0 to 127, the maximum I/O
Rockwell
SLC500
Rockwell
PLC-5
Rockwell
ControllLogix 5000
Rockwell
MicroLogix 1500
Omron
SYSMAC CS1
Omron
SYSMAC CJ
Omron
SYSMAC CJ1M
HITACHI
S10mini
HITACHI
S10V
YOKOGAWA
FA-M3
*2 Designate the DIO Start Address within the range shown below.
6
Word Address
LS20 to LS1999
size used per slave will differ depending on each company's master unit specifi-
cations.
The I/O size that each company supports is shown as below.
PLC Series
Input Area Size (word)
0 to 64
0 to 64
0 to 127
0 to 127
0 to 32
0 to 100
0 to 100
0 to 127
0 to 127
0 to 127
20 ≤ DIO Start Address ≤ 2000 - Input Area Size - Output Area Size
e.g: When Input Area Size =4, and Output Area Size =16,
the setting range of the DIO Start Address should be:
20 ≤ DIO Start Address ≤ 1980
GP-PRO/PBIII for Windows Device/PLC Connection Manual
Remarks
0 to 127
*1
0 to 127
*1
*2
Output Area Size (word)
0 to 64
0 to 64
0 to 127
0 to 127
o to32
o to 100
o to 100
0 to 127
0 to 127
0 to 127
L/H