2 Installation

2.1 Location Requirements

The inverter with IP65 can be installed indoors or outdoors.
Selecting an optimal location for the inverter is critical for its operating safety as
well as the expected efficiency and service life. Considerations for the location
include:
1.
The structure should be capable of withstanding a force of four times the
weight of the inverter and be suitable for the dimensions of the inverter.
2.
Install the inverter where it is convenient for installation, cable connection
and service.
3.
Do not install the inverter in the living area or bedrooms. The noise
during its operation may affect daily life.
4.
The location should be not accessible to children.
5.
The ambient temperature and relative humidity should meet the following
requirements.
Max.
+60° C
6.
Only mount the inverter on a non-flammable surface or a wooden
structure. Keep away from flammable materials or gas. Do not enclose
the inverter into a tight confinement.
Flammable wall
Min.
-25° C
Flammable material or
gas near the installation
Max. RH
+100%
Enclosed cabinet