Basic note
Installation
The printing system may only be assembled and installed by Service personnel.
The printing system must have a dedicated electrical connection or type B plug
connection (complying with VDE directives, EN 60950).
Do not route the lines and cables in such a way that they can be trodden on or
tripped over.
A fume hood should be installed over the fuser module (without a smoke
detector). In very seldom cases, paper that has been caught in the fuser module
will be damaged by the infrared fusing and will begin to smoke. However, even
in this case there is no danger of fire because the affected component is
immediately isolated from the remaining printing system by sealed bulkheads.
This bulkhead is part of a proven safety concept and does not affect the
availability of the printing system after the jammed paper has been removed.
All printing system accessories and options must comply with statutory
regulations and directives for safety, electromagnetic compatibility,
telecommunications terminal devices as well as with the specifications published
by Océ Printing Systems GmbH.
The installation of other accessories may constitute a violation of these
requirements and directives, and may also damage the printing system.
Consult Service personnel for details on which accessories and options are
permitted for the printing system.
With the exception of optical wave guide connections, all data, signalling,
process, measurement and control lines mapping the printing system with other
devices must be properly grounded.
Data transmission lines should neither be connected nor disconnected during
electrical storms.
Repairs
Repairs to the printing system must only be carried out by Service personnel.
Access to locked areas and areas that can only be opened with special tools is
reserved for Service. Opening a Service area without authorisation and
improperly effected repairs may put operators at considerable risk.
The access ticket used by the Service technician ensures that the printing system
cannot be used via a LAN from a remote operator panel during repair work.
Fire
Poisonous gases can occur in any fire. They can also result from the printing
system Océ VarioStream 9000.
Self-contained breathing apparatus must be worn when fighting fire or smoke
emission. Notes to this effect should be deposited at the fire alarm centre and with
the local fire department.