S350 Series 24-Port (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
If you do not know the IP address of the switch, see Discover or Change the Switch IP
Address on page 12.
The login window opens.
4. Enter the switch's password in the Password field.
The default password is password.
The System Information page displays.
5. Select System > Management > System CPU Status > CPU Threshold.
6. Specify the thresholds:
Rising Threshold. Notification is generated when the total CPU utilization exceeds
this threshold value over the configured time period. The range is 1 to 100.
Rising Interval. This utilization monitoring time period can be configured from 5 to
86400 seconds in multiples of 5 seconds.
Falling Threshold. Notification is triggered when the total CPU utilization falls below
this level for a configured period of time.
The falling utilization threshold must be equal to or less than the rising threshold
value. The falling utilization threshold notification is sent only if a rising threshold
notification was sent previously. Configuring the falling utilization threshold and time
period is optional. If the Falling CPU utilization settings are not configured, the switch
uses the same values as the values that are used for the Rising CPU utilization. The
range is 1 to 100.
Falling Interval. The utilization monitoring time period can be configured from
5 seconds to 86400 seconds in multiples of 5 seconds.
Free Memory Threshold. The free memory threshold value for the CPU in KB.
7. Click the Apply button.
Your settings are saved.
Configure System Information
39