NETGEAR S350 Series User Manual page 130

24-port (poe+) and 48-port gigabit ethernet smart managed pro switches with 2 or 4 sfp ports
Hide thumbs Also See for S350 Series:
Table of Contents

Advertisement

S350 Series 24-Port (PoE+) and 48-Port Gigabit Ethernet Smart Managed Pro Switches
The previous figure does snot show all columns on the page.
6. Select whether to display physical interfaces, LAGs, or both by clicking one of the following
links above the table heading:
1 (the unit ID of the switch). Only physical interfaces are displayed. This is the default
setting.
LAG. Only LAGs are displayed.
All. Both physical interfaces and LAGs are displayed.
7. Select one or more interfaces by taking one of the following actions:
To configure a single interface, select the check box associated with the port, or type
the port number in the Go To Interface field and click the Go button.
To configure multiple interfaces with the same settings, select the check box
associated with each interface.
To configure all interfaces with the same settings, select the check box in the heading
row.
8. In the PVID field, specify the VLAN ID to assign to untagged or priority-tagged frames
received on the port.
The default is 1. The range is from 2 to 4093, excluding 4089.
9. In the VLAN Member field, specify the VLAN ID or list of VLANs of a member port.
VLAN IDs range from 2 to 4093, excluding 4089. The default is 1. Use a hyphen (-) to
specify a range or a comma (,) to separate VLAN IDs in a list. Spaces and zeros are not
permitted.
10. In the VLAN Tag field, specify the VLAN ID or list of VLANs of a tagged port.
VLAN IDs range from 2 to 4093, excluding 4089. Use a hyphen (-) to specify a range or a
comma (,) to separate VLAN IDs in a list. Spaces and zeros are not permitted. You can
specify port tagging for the VLAN only if the port that you want to add as a tagged port is
also member of the VLAN. To reset the VLAN tag configuration to the defaults, use the
None keyword.
11. From the Acceptable Frame menu, specify one if the following types of frames that can be
received on the port:
Admit All. Untagged frames or priority-tagged frames that are received on the port
are accepted and assigned the value of the port VLAN ID for the port. This is the
default selection.
VLAN Only. Untagged frames or priority-tagged frames that are received on the port
are discarded.
Admit Untagged Only. Untagged frames that are received on the port are accepted.
With the Admit All and VLAN Only selections, VLAN-tagged frames are forwarded in
accordance to the 802.1Q VLAN specification.
12. From the Ingress Filtering menu, select one of the following options:
Enable. The frame is discarded if the port is not a member of the VLAN with which
this frame is associated. In a tagged frame, the VLAN is identified by the VLAN ID in
Configure Switching
130
User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs324tpGs348tGs324t

Table of Contents