Optical Fiber
Fiber Cable Type
Typical Distance
Wavelength
Optical Power
Note: When connecting 40 km single-mode fiber over a short distance,
we recommend putting an attenuator to prevent the transceiver from
being damaged by excessive optical power.
Typical Distance: To reach the typical distance of a specified fiber
transceiver, please refer to the following formula: Link budget(dB) >
dispersion penalty(dB) + total link loss(dB).
Power
Input Voltage
Input Current @ 24
VDC
Connection
Inrush current
Overload Current
Protection
Reverse Polarity
Protection
Physical Characteristics
Housing
Dimension
(W x H x D)
Weight
Installation
Environmental
Operating Temperature
Storage Temperature
Ambient Relative
Humidity
Typical (nm)
TX Range (nm)
RX Range (nm)
TX Range (dBm)
RX Range (dBm)
Link Budget (dB)
Dispersion
Penalty (dB)
12/24/48 VDC (9.6 to 60 VDC),
2 redundant inputs
0.1 A (IE-SW-BL05-5TX)
0.11 A (IE-SW-BL05-4TX-1SC/1SCS/1ST)
0.07 A (IE-SW-BL08-8TX)
0.1 A (IE-SW-BL08-7TX-1SC/1ST)
0.11 A (IE-SW-BL08-7TX-1SCS)
0.14 A (IE-SW-BL08-8TX-2SC/2ST)
0.15 A (IE-SW-BL08-6TX-2SCS)
One removable 4-pin terminal block
IE-SW-BL05 series:
Max. 6.24A @ 24VDC (0.1 - 1ms)
IE-SW-BL08 series:
Max. 8.81A @ 24VDC (0.1 - 1ms)
Present
Present
IP30 protection, metal case
IE-SW-BL05 series: 30x 115 x 70 mm
IE-SW-BL08 series: 50x 114 x 70 mm
IE-SW-BL05 series: 175 g
IE-SW-BL08 series: 275 g
DIN-rail, Wall Mounting (with optional kit)
-10 to 60°C (14 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
-40 to 85°C (-40 to 185°F)
5 to 95% (non-condensing)
Multi-mode
50/125 µm
OM1
800 MHz*Km
4 km
5 km
1300
1260 to 1360
1100 to 1600
-10 to -20
-3 to -32
12
3
- 15 -
100Base FX
Single-mode
1280 to 1340
1100 to 1600
-3 to -34
G.652
40 km
1310
0 to -5
29
1