Siemens QMX3.P30 Instruction Manual page 14

Wall-mounted sensors and room operator units
Hide thumbs Also See for QMX3.P30:
Table of Contents

Advertisement

Display
Ports/interfaces
Housing protection
Protection class
Ambient conditions
Standards and directives
Color
Weight [g]
NOTICE
FCC warning
14 / 16
QMX3... Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode
Siemens Building Technologies
Type
Information displayed depends on the application in the
room automation station.
Type of port between room automation station and room
operator unit
Baud rate
Standard KNX plug
Cable type
Single cable length (from room automation station to room
operator unit)
Cables must comply with KNX specifications, see TRA Install. manual, CM111043
Protection standard as per EN 60529
Insulation protection class
IEC 721
Environmental conditions
Temperature
Humidity
Mechanical conditions
EU conformity (CE)
compliance
compliance
CSA compliance
RCM Mark conformity (EMC)
The product environmental declaration CM2E1602
design and assessments (RoHS compliance, materials composition, packaging, environmental benefit,
disposal)
Front housing
Models QMX3.Pxx
Models QMX3.Pxx-1BSC
Operator unit
Base plate
Packaging
Total
*)
The documents can be downloaded from http://siemens.com/bt/download.
Notes on FCC rules
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Segment LCD
– Room temperature, humidity, CO
– Setpoint adjustment
– Control mode
– Manually selected fan speed
– Control sequence
– Scenes (LED next to the button)
– etc.
KNX / PL-Link
9.6 kbps
Wire diameter0.8 mm, max. 1.0 mm
(solid conductors only)
Solid conductors 2-core, twisted pair
<1000 m
IP 30
III
Normal operation
Class 3K5
0...50 °C
< 85 % rh
Class 3M2
CM2T1602xx
UL916
Part 15 of the FCC rules
C22.2 No 205 – Signal equipment
C22.2 No 0 – General Requirements
AS/NZS 61000-6-3
*)
contains data on environmentally compatible product
Titanium white similar to RAL9010
Black similar to RAL9005
QMX3.
P02
P30
91
84
20
20
64
64
175
168
*)
Transport
Class 2K3
– 25...70 °C
< 95 % rh
Class 2M2
*)
P34
P37
P40
P70
122
124
85
20
20
20
64
64
64
169
206
208
181
CM2N1602en_07
2
P74
97
132
20
20
64
64
216
2017-05-22